弹性分离器在颌面骨折复位中的应用。

Use of Elastomeric Separators in Maxillofacial Fracture Reduction.

作者信息

Mohanty Rajat, Jha Chhaya

机构信息

Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, Odisha 751024 India.

Ramakrishna Mission Tb Sanatorium, Dibdih, Near Dibdih Flyover, Ranchi, Jharkhand 834002 India.

出版信息

J Maxillofac Oral Surg. 2021 Dec;20(4):700-701. doi: 10.1007/s12663-021-01525-0. Epub 2021 Feb 22.

Abstract

BACKGROUND

Management of maxilla and mandibular fractures are based on the principles of reduction, fixation and immobilization of the fracture segments.

PURPOSE

One of the processes of reduction is to apply continuous and gradual elastic traction by placing elastics from the upper and lower arch bars in a definite manner and direction as per the fracture line. Orthodontic elastic separators are versatile, and the major advantage is the higher traction forces as compared to conventional elastics.

METHODS

Prestretched separator elastics were guided over the arch bar or fixed orthodontic appliances to provide desired traction.

RESULTS

Orthodontic elastic separators are therefore versatile, and the major advantage is the higher traction forces as compared to conventional elastics. They provide an edge over the use of wires as they tend to break off by work hardening.

CONCLUSION

Therefore, we have adapted orthodontic separators and have used them in place of conventional elastics for the last 10 years with appreciable results after taking informed consent from the patients.

摘要

背景

上颌骨和下颌骨骨折的治疗基于骨折段复位、固定和制动的原则。

目的

复位过程之一是按照骨折线,以上下牙弓杆特定的方式和方向放置弹力线,施加持续且逐渐增大的弹性牵引。正畸弹性分离器用途广泛,主要优点是与传统弹力线相比,牵引力更大。

方法

将预拉伸的分离器弹力线引导至牙弓杆或固定正畸矫治器上,以提供所需的牵引力。

结果

因此,正畸弹性分离器用途广泛,主要优点是与传统弹力线相比,牵引力更大。与使用金属丝相比,它们具有优势,因为金属丝往往会因加工硬化而折断。

结论

因此,在获得患者知情同意后,过去10年来我们采用了正畸分离器并将其用于替代传统弹力线,取得了显著效果。

相似文献

1
Use of Elastomeric Separators in Maxillofacial Fracture Reduction.
J Maxillofac Oral Surg. 2021 Dec;20(4):700-701. doi: 10.1007/s12663-021-01525-0. Epub 2021 Feb 22.
6
Comparison of Erich arch bar versus embrasure wires for intraoperative intermaxillary fixation in mandibular fractures.
Oral Maxillofac Surg. 2018 Dec;22(4):419-428. doi: 10.1007/s10006-018-0723-9. Epub 2018 Oct 9.
7
The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators.
Lasers Med Sci. 2014 Mar;29(2):559-64. doi: 10.1007/s10103-012-1258-1. Epub 2013 Jan 20.
8
Separation and pain perception of Elastomeric, Kesling and Kansal separators.
Dental Press J Orthod. 2019 May 20;24(2):42-48. doi: 10.1590/2177-6709.24.2.042-048.oar.
9
Comparison of the Force Released by Intermaxillary Elastics Used for Different Time Periods.
Turk J Orthod. 2019 Dec 1;32(4):190-194. doi: 10.5152/TurkJOrthod.2019.18022. eCollection 2019 Dec.
10
Dynamic force decay evaluation of latex and non-latex orthodontic elastics.
J Orofac Orthop. 2022 Sep;83(5):318-324. doi: 10.1007/s00056-021-00319-w. Epub 2021 Jun 29.

本文引用的文献

2
Conservative treatment of a mandibular condyle fracture: Comparing intermaxillary fixation with screws or arch bar. A randomised clinical trial.
J Craniomaxillofac Surg. 2015 Jun;43(5):671-6. doi: 10.1016/j.jcms.2015.03.010. Epub 2015 Mar 27.
3
Perceived vs measured forces of interarch elastics.
Am J Orthod Dentofacial Orthop. 2012 Mar;141(3):298-306. doi: 10.1016/j.ajodo.2011.08.027.
4
Management of fractured mandibles without the use of intermaxillary wire fixation.
J Oral Maxillofac Surg. 2002 Dec;60(12):1435-8; discussion 1439. doi: 10.1053/joms.2002.36100.
5
The use of orthodontic chain elastic for temporary intermaxillary fixation.
Br J Oral Maxillofac Surg. 1993 Aug;31(4):250-1. doi: 10.1016/0266-4356(93)90150-u.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验