Suppr超能文献

与全层全软组织股四头肌肌腱自体移植的缝合固定相比,连续环带技术具有更大的刚度和更小的伸长率。

Continuous-Loop Tape Technique Has Greater Stiffness and Less Elongation Compared With Tied-Suture Fixation of Full-Thickness All-Soft Tissue Quadriceps Tendon Autografts.

作者信息

Gibbs Christopher M, Winkler Philipp W, Tisherman Robert T, Chan Calvin K, Diermeier Theresa A, Debski Richard E, Musahl Volker

机构信息

Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Department of Orthopaedic Sports Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.

出版信息

Orthop J Sports Med. 2021 Nov 11;9(11):23259671211054108. doi: 10.1177/23259671211054108. eCollection 2021 Nov.

Abstract

BACKGROUND

Many graft fixation techniques are utilized for full-thickness soft tissue quadriceps tendon autografts during anterior cruciate ligament reconstruction (ACLR).

PURPOSE

To determine the tensile properties of all-soft tissue quadriceps tendon graft fixation using a tied-suture versus continuous-loop tape technique. It was hypothesized that the continuous-loop tape technique would have less cyclic elongation and greater ultimate load to failure and stiffness compared with a commonly used tied-suture technique.

STUDY DESIGN

Controlled laboratory study.

METHODS

Sixteen fresh-frozen human knee specimens were used to harvest a full-thickness all-soft tissue quadriceps tendon graft; half were secured using a Krackow suture technique with 2 braided sutures, and half were secured using a continuous-loop tape suspensory fixation button with a rip-stop stitch. Cyclic and permanent elongation, toe- and linear-region stiffness, and ultimate load were determined. Statistical analysis was performed at <.05.

RESULTS

The tied-suture fixation group demonstrated significantly higher permanent elongation (11.7 ± 3.6 vs 4.2 ± 1.0 mm, < .001) and cyclic elongation (5.9 ± 1.3 vs 2.0 ± 0.4 mm, < .001) compared with the continuous-loop tape fixation group. There was a significantly higher linear-region stiffness with continuous-loop tape fixation compared with tied-suture fixation (98.8 ± 12.7 vs 85.5 ± 7.5 N/mm, = .022). No significant difference in ultimate load between groups (517.1 ± 149.2 vs 465.6 ± 64.6 N) was found. The mode of failure was tendon pull-through for the continuous-loop tape group and suture breakage in the tied-suture group ( < .001).

CONCLUSION

Continuous-loop tape fixation is superior to tied-suture fixation in regard to elongation and stiffness for all-soft tissue quadriceps tendon grafts, but there was no significant difference in ultimate load.

CLINICAL RELEVANCE

Continuous-loop tape fixation of all-soft tissue quadriceps tendon grafts for ACLR is a valid technique with superior tensile properties.

摘要

背景

在前交叉韧带重建(ACLR)过程中,许多移植物固定技术被用于全层软组织股四头肌肌腱自体移植物。

目的

确定使用打结缝线与连续环带技术对全软组织股四头肌肌腱移植物进行固定的拉伸特性。假设与常用的打结缝线技术相比,连续环带技术的循环伸长更小,极限破坏载荷和刚度更大。

研究设计

对照实验室研究。

方法

使用16个新鲜冷冻的人膝关节标本获取全层全软组织股四头肌肌腱移植物;一半使用Krackow缝线技术用2根编织缝线固定,另一半使用带防撕裂缝线的连续环带悬吊固定纽扣固定。测定循环伸长和永久伸长、趾部和线性区域刚度以及极限载荷。统计学分析采用P<0.05。

结果

与连续环带固定组相比,打结缝线固定组的永久伸长(11.7±3.6 vs 4.2±1.0 mm,P<0.001)和循环伸长(5.9±1.3 vs 2.0±0.4 mm,P<0.001)明显更高。与打结缝线固定相比,连续环带固定的线性区域刚度明显更高(98.8±12.7 vs 85.5±7.5 N/mm,P=0.022)。两组之间的极限载荷无显著差异(517.1±149.2 vs 465.6±64.6 N)。连续环带组的失效模式为肌腱拉出,打结缝线组为缝线断裂(P<0.001)。

结论

对于全软组织股四头肌肌腱移植物,连续环带固定在伸长和刚度方面优于打结缝线固定,但极限载荷无显著差异。

临床意义

ACLR中全软组织股四头肌肌腱移植物的连续环带固定是一种具有优异拉伸特性的有效技术。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a013/8591645/cc5f15444220/10.1177_23259671211054108-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验