Suppr超能文献

一种称重传感器设置、Ito 和计时站立负荷测试在测量有和无脊柱后凸的老年人肌肉力量和耐力的重测信度。

Test-retest reliability of a load cell setup, Ito, and timed loaded standing tests for measuring muscle strength and endurance in older adults with and without hyperkyphosis.

机构信息

Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran.

Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran; Rehabilitation Research Center, Iran University of Medical Sciences, Tehran, Iran.

出版信息

Musculoskelet Sci Pract. 2022 Apr;58:102475. doi: 10.1016/j.msksp.2021.102475. Epub 2021 Nov 10.

Abstract

BACKGROUND

The association of back muscle weakness with greater thoracic kyphosis has been widely documented. Reliable and easy-to-use techniques are needed to monitor changes in muscle function over time and assess the effectiveness of therapeutic interventions. Therefore, the present study aimed to evaluate the test-retest reliability of a designed load-cell setup and two clinical tests, namely Ito and Timed loaded standing (TLS) tests for measuring back muscle function (i.e., strength and endurance) in older adults with and without hyperkyphosis.

METHOD

Fifty-three older people (28 with thoracic hyperkyphosis and 25 normal age-matched controls) completed the present test-retest reliability study. A two-way random model of the Intraclass Correlation Coefficient (ICC) was used to estimate relative reliability. Absolute reliability was assessed by calculating Standard Error of the Measurements (SEM) and Minimal Detectable Change (MDC).

RESULTS

The findings showed excellent test-retest reliability in all performed tests for this population (ICC = 0.95-0.99). In addition, the MDC values for measuring endurance time via load cell, Ito, and TLS tests in the hyperkyphosis group, were 16.5, 28.2, and 35.1 s, respectively. These values ranged from 36 to 39 s for the control group.

CONCLUSION

The present study suggests high test-retest reliability of the designed load-cell setup, Ito, and TLS for assessing back extensor muscle strength and endurance in older adults with and or without hyperkyphosis.

摘要

背景

背部肌肉力量与较大的胸椎后凸之间的关联已得到广泛证实。需要可靠且易于使用的技术来监测肌肉功能随时间的变化,并评估治疗干预措施的效果。因此,本研究旨在评估设计的测力装置以及 Ito 和计时站立(TLS)测试这两种临床测试在测量有和无胸椎后凸的老年人背部肌肉功能(即力量和耐力)方面的测试-重测信度。

方法

53 名老年人(28 名患有胸椎后凸,25 名年龄匹配的正常对照组)完成了本测试-重测信度研究。采用组内相关系数(ICC)的双向随机模型来估计相对可靠性。通过计算测量标准误差(SEM)和最小可检测变化(MDC)来评估绝对可靠性。

结果

对于该人群的所有测试,研究结果均显示出极好的测试-重测信度(ICC=0.95-0.99)。此外,在胸椎后凸组中,通过测力装置、Ito 和 TLS 测试测量耐力时间的 MDC 值分别为 16.5、28.2 和 35.1 秒,而对照组的这些值范围为 36 至 39 秒。

结论

本研究表明,设计的测力装置、Ito 和 TLS 用于评估有和无胸椎后凸的老年人背部伸肌力量和耐力,具有很高的测试-重测信度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验