Abstract

AIM

To compare the intraocular pressure (IOP) peaks and fluctuations using water drinking tests (WDTs) and mean diurnal IOP among Filipino patients with normal eyes and glaucoma suspects.

METHODS

This prospective study included normal and glaucoma suspect patients. Each patient underwent both WDT and mean diurnal examination on separate visits. For mean diurnal examination, IOP was recorded every 2h for 8h while in WDT, IOP was recorded prior to WDT, and post-WDT at 5, 15, 30, 45, and 60min. IOP peak was recorded as the highest IOP for both methods, and IOP fluctuation was recorded as highest IOP minus lowest IOP.

RESULTS

With the comparison of diagnostic tests, both normal eyes and glaucoma suspect groups, the peak IOP was caught at 15min. Comparative analysis of both groups also showed that the peak IOP measurements were statistically higher for the WDT compared to mean diurnal IOP (=0.039, =0.048 under normal group and =0.032 and =0.031 under glaucoma suspect group). Similarly, the WDT had a statistically higher mean IOP fluctuation score than the mean diurnal IOP method in both groups (=0.003, =0.011 under normal group; =0.002 and =0.005 under glaucoma suspect group).

CONCLUSION

This study shows that WDT is a comparable diagnostic exam in predicting IOP fluctuations than mean diurnal measurement. WDT is a promising diagnostic procedure for risk assessment in glaucoma.

摘要

目的

比较菲律宾正常眼和青光眼疑似患者饮水试验(WDT)与平均昼夜眼压的眼压峰值和波动情况。

方法

这项前瞻性研究纳入了正常和青光眼疑似患者。每位患者在不同时间分别接受WDT和平均昼夜眼压检查。对于平均昼夜眼压检查,眼压每2小时记录一次,共记录8小时;而在WDT中,眼压在WDT前以及WDT后5、15、30、45和60分钟记录。两种方法的眼压峰值均记录为最高眼压,眼压波动记录为最高眼压减去最低眼压。

结果

在诊断测试的比较中,正常眼组和青光眼疑似组的眼压峰值均在15分钟时出现。两组的比较分析还显示,与平均昼夜眼压相比,WDT的眼压峰值测量在统计学上更高(正常组=0.039,=0.048;青光眼疑似组=0.032和=0.031)。同样,在两组中,WDT的平均眼压波动评分在统计学上均高于平均昼夜眼压方法(正常组=0.003,=0.011;青光眼疑似组=0.002和=0.005)。

结论

本研究表明,与平均昼夜测量相比,WDT在预测眼压波动方面是一种可比的诊断检查。WDT是一种有前景的青光眼风险评估诊断方法。

相似文献

本文引用的文献

6
Applications of the water drinking test in glaucoma management.饮水试验在青光眼管理中的应用。
Clin Exp Ophthalmol. 2017 Aug;45(6):625-631. doi: 10.1111/ceo.12925. Epub 2017 Mar 9.
10

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验