Suppr超能文献

记录股外侧肌 F 波的最佳股神经刺激部位。

Optimal stimulation site of the femoral nerve to record F waves from the vastus lateralis muscle.

机构信息

Department of Clinical Rehabilitation Research, Tanabe Central Hospital, Wakayama, Japan.

Graduate School of Health Sciences, Graduate School of Kansai University of Health Sciences, Osaka, Japan.

出版信息

Muscle Nerve. 2022 Feb;65(2):242-246. doi: 10.1002/mus.27468. Epub 2021 Dec 14.

Abstract

INTRODUCTION/AIMS: The conventional recording of F waves from the vastus lateralis muscle (VL) may not accurately measure the F-wave amplitude, as the F-wave latency is short and overlaps with the M wave. However, the optimal stimulation site of the femoral nerve for recording M and F waves separately from the VL remains unclear. In this study we aimed to determine the optimal stimulation site of the femoral nerve to record M and F waves separately from the VL.

METHODS

Stimulating electrodes were placed medial and lateral to the VL (50%, 60%, 70%, and 80% of the distance along a line extending from the proximal to the distal thigh). Each site of the distal thigh was electrically stimulated at random and F waves were recorded from the VL. Each stimulation site was considered to be success if there was no severe pain or discomfort during electrical stimulation of the femoral nerve and no overlap between the recorded M and F waves; otherwise, it was determined as a failure.

RESULTS

Thirteen healthy men participated in the study. F waves were successfully recorded in five participants at the 50% sites, eight participants at the 60% site, and 12 participants at the 70% and 80% sites. In cases of failed F-wave measurement, the participants experienced severe pain or discomfort due to electrical stimulation.

DISCUSSION

M and F waves could be recorded separately from the VL when the relevant branch of the femoral nerve was stimulated in the distal thigh.

摘要

介绍/目的:从股外侧肌(VL)记录 F 波可能无法准确测量 F 波幅度,因为 F 波潜伏期短,与 M 波重叠。然而,记录 VL 上的 M 和 F 波的最佳股神经刺激部位尚不清楚。在这项研究中,我们旨在确定记录 VL 上的 M 和 F 波的最佳股神经刺激部位。

方法

刺激电极放置在 VL 的内侧和外侧(从近端到大腿的延伸线上的距离的 50%、60%、70%和 80%)。随机对每个大腿远端部位进行电刺激,并从 VL 记录 F 波。如果在股神经电刺激过程中没有剧烈疼痛或不适,并且记录的 M 和 F 波没有重叠,则认为每个刺激部位都是成功的;否则,它被确定为失败。

结果

13 名健康男性参与了这项研究。在 50%的部位,有 5 名参与者成功记录了 F 波,在 60%的部位,有 8 名参与者成功记录了 F 波,在 70%和 80%的部位,有 12 名参与者成功记录了 F 波。在 F 波测量失败的情况下,由于电刺激,参与者经历了剧烈的疼痛或不适。

讨论

当刺激大腿远端股神经的相关分支时,可以从 VL 上单独记录 M 和 F 波。