Cordlife Group Limited, Singapore, Singapore.
StemLife Berhad, Kuala Lumpur, Malaysia.
Transfus Med. 2022 Feb;32(1):82-87. doi: 10.1111/tme.12834. Epub 2021 Dec 3.
To evaluate the effects of cryopreservation in post-thaw umbilical cord blood units for the survivability of Gram-positive bacteria strains.
Microbial screening is required for all cord blood units (CBUs). Four gram-positive contaminants were documented to survive cryopreservation poorly and isolation of other contaminants were reported.
Forty-eight contaminated CBUs detected with either Staphylococcus epidermidis, Corynebacterium species, Peptostreptococcus or Streptococcus species before cryopreservation were used in this study. CBUs were processed, DMSO-infused and microbial screened before cryopreservation. Post-thaw microbial screening was achieved using 1 and 10 ml inoculants in BACTEC culture bottles. Positive bottles were subjected for microbial identification and results were compared with those from pre-freeze.
A higher rate of microbial contamination was found using the 10 ml inoculant. Screening of 11 CBUs did not detect any contaminants while 30 CBUs screened detected more than one unknown contaminants and majority of contaminants were identified to be gram-negative species.
A higher inoculation volume used at post-thaw for microbial screening improves contamination detection but leads to the loss of precious cord blood. Some contaminants did not survive cryopreservation or were not identified due to their low microbial levels. Contrasting contaminants found at post-thaw suggest the improvements made in detection and identification of contaminants over the years.
评估冻存对革兰阳性菌菌株存活能力的影响。
所有脐带血单位(CBU)都需要进行微生物筛查。有报道称,有 4 种革兰阳性污染物在冻存过程中存活能力差,并且其他污染物也有被分离出来的情况。
本研究使用了 48 个在冻存前检测出表皮葡萄球菌、棒状杆菌属、消化链球菌或链球菌属污染的 CBU。CBU 在冻存前进行处理、DMSO 灌注和微生物筛查。在冻存后使用 1 和 10ml 接种物在 BACTEC 培养瓶中进行微生物筛查。阳性瓶进行微生物鉴定,结果与冻存前进行比较。
使用 10ml 接种物时,微生物污染的检出率更高。11 个 CBU 筛查未发现任何污染物,而 30 个 CBU 筛查出一种以上未知污染物,大多数污染物被鉴定为革兰氏阴性菌。
在冻存后进行微生物筛查时使用较大的接种量可以提高污染检测率,但会导致宝贵的脐带血损失。一些污染物由于其较低的微生物水平而无法存活或无法鉴定。在冻存后发现的不同污染物提示多年来在检测和鉴定污染物方面取得了改进。