PURPOSE

The aim of this proof-of-concept study is to propose a simplified personalized kidney dosimetry procedure in Lu peptide receptor radionuclide therapy (PRRT) for neuroendocrine tumors and metastatic prostate cancer. It relies on a single quantitative SPECT/CT acquisition and multiple radiometric measurements executed with a collimated external probe, properly directed on kidneys.

METHODS

We conducted a phantom study involving external count-rate measurements in an abdominal phantom setup filled with activity concentrations of Tc, reproducing patient-relevant organ effective half-lives occurring in Lu PRRT. GATE Monte Carlo (MC) simulations of the experiment, using Tc and Lu as sources, were performed. Furthermore, we tested this method via MC on a clinical case of Lu-DOTATATE PRRT with SPECT/CT images at three time points (2, 20 and 70 hrs), comparing a simplified kidney dosimetry, employing a single SPECT/CT and probe measurements at three time points, with the complete MC dosimetry.

RESULTS

The experimentally estimated kidney half-life with background subtraction applied was compatible within 3% with the expected value. The MC simulations of the phantom study, both with Tc and Lu, confirmed a similar level of accuracy. Concerning the clinical case, the simplified dosimetric method led to a kidney dose estimation compatible with the complete MC dosimetry within 6%, 12% and 2%, using respectively the SPECT/CT at 2, 20 and 70 hrs.

CONCLUSIONS

The proposed simplified procedure provided a satisfactory accuracy and would reduce the imaging required to derive the kidney absorbed dose to a unique quantitative SPECT/CT, with consequent benefits in terms of clinic workflows and patient comfort.

摘要

目的

本概念验证研究的目的是为神经内分泌肿瘤和转移性前列腺癌的镥肽受体放射性核素治疗(PRRT)提出一种简化的个性化肾脏剂量测定程序。它依赖于一次定量SPECT/CT采集以及使用准直外部探头对肾脏进行适当定向的多次放射性测量。

方法

我们进行了一项体模研究,在一个充满锝活度浓度的腹部体模设置中进行外部计数率测量,再现镥PRRT中与患者相关的器官有效半衰期。使用锝和镥作为源对该实验进行了GATE蒙特卡罗(MC)模拟。此外,我们通过MC在一个镥-奥曲肽PRRT临床病例上测试了该方法,该病例在三个时间点(2、20和70小时)有SPECT/CT图像,将采用在三个时间点进行一次SPECT/CT和探头测量的简化肾脏剂量测定法与完整的MC剂量测定法进行比较。

结果

应用背景扣除后实验估计的肾脏半衰期与预期值相差在3%以内。体模研究的MC模拟,无论是使用锝还是镥,都证实了类似的准确度水平。关于临床病例,简化剂量测定法分别使用2小时、20小时和70小时的SPECT/CT,得出的肾脏剂量估计值与完整的MC剂量测定法相差在6%、12%和2%以内。

结论

所提出的简化程序提供了令人满意的准确度,并且将得出肾脏吸收剂量所需的成像减少到一次独特的定量SPECT/CT,从而在临床工作流程和患者舒适度方面带来益处。