Abstract

This study evaluated the effect of the use of glass ionomer cement (GIC) and flowable bulk-fill resin composite (BFRC) for filling pulp chambers and the type of high-speed handpiece light used on dentin removal during access preparation for endodontic retreatment in molar teeth. Twenty maxillary molars were treated endodontically. BFRC (Opus Bulk Fill Flow APS, FGM) was used to fill the pulp chamber and replace coronal dentin (n = 10). In the remaining teeth, the pulp chamber was filled with GIC (Maxion R, FGM). Conventional resin composite (Opallis, FGM) was used to restore the enamel layer in all teeth. The samples in each group were divided into two subgroups, and the root canals were reaccessed using a handpiece with white or ultraviolet light. The teeth were scanned using micro-CT before and after root canal reaccess. The dentin volume removed was calculated and analyzed using 2-way analysis of variance and Tukey's test (α = 0.05). The crown and pulp chamber locations with dentin removal are described using frequency distribution. During the access, fewer pulp chamber walls were affected and a lower volume of dentin was removed from the pulpal floor in the group restored with GIC than in the group restored with BFRC. No effect was observed on the coronal dentin walls with respect to the filling protocols and type of light used. For dentin removal from the pulp chamber, handpieces with white light performed better than those with ultraviolet light, irrespective of the filling protocol used. The use of GIC to fill the pulp chamber and use of white handpiece light reduced dentin removal from the pulpal floor and resulted in fewer affected dentin walls.

摘要

本研究评估了在磨牙的根管再治疗中,使用玻璃离子水门汀(GIC)和流动性块状填充树脂复合材料(BFRC)填充髓室以及使用高速手机灯的类型对牙本质去除的影响。共对 20 颗上颌磨牙进行根管治疗。BFRC(Opus Bulk Fill Flow APS,FGM)用于填充髓室并替代冠部牙本质(n = 10)。在其余牙齿中,使用 GIC(Maxion R,FGM)填充髓室。所有牙齿均使用常规树脂复合材料(Opallis,FGM)恢复牙釉质层。每组样本分为两个亚组,使用带白光或紫外线光的手机进行根管再进入。在根管再进入前后使用 micro-CT 扫描牙齿。使用双因素方差分析和 Tukey 检验(α = 0.05)分析计算并分析去除的牙本质体积。使用频率分布描述去除牙本质的冠部和髓室位置。在进入过程中,与用 BFRC 修复的组相比,用 GIC 修复的组中,更少的髓室壁受到影响,并且从髓室底部去除的牙本质体积更少。使用的填充方案和光的类型对冠部牙本质壁没有影响。对于从髓室去除牙本质,白光手机的效果优于紫外线手机,与使用的填充方案无关。使用 GIC 填充髓室并使用白光手机灯光可减少从髓室底部去除牙本质,并减少受影响的牙本质壁数量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验