使用剪切波弹性成像研究超声检查时手臂外展角度和衬垫支撑对超声技师冈上肌硬度的影响。

Study on the effects of arm abduction angle and cushion support during sonographic examination on the stiffness of supraspinatus muscle of sonographers using shear wave elastography.

机构信息

Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, Hong Kong.

出版信息

J Occup Health. 2021 Jan;63(1):e12306. doi: 10.1002/1348-9585.12306.

Abstract

OBJECTIVES

The incidence of work-related musculoskeletal disorder remains high in sonography. The aims of this study are to determine the changes in muscle stiffness with different arm abduction angles, and to investigate the effect of cushion support on reducing muscle load in the supraspinatus when sonographers scan with the arm abducted to different angles.

METHODS

This is a prospective crossover study. Twenty-three healthy female subjects aged between 20 and 23 years were included. Subjects were instructed to simulate performing standardized abdominal ultrasound scans. The changes in muscle stiffness of supraspinatus, measured as shear modulus, at rest and at 30°, 45°, and 60° arm abduction angles with and without cushion support were evaluated using shear-wave elastography. Styrofoam support was used for the cushion support.

RESULTS

Mean shear moduli of supraspinatus were 27.77 ± 5.84 kPa at rest and 41.63 ± 7.09 kPa, 63.88 ± 14.43 kPa, and 89.76 ± 16.55 kPa for 30°, 45°, and 60° arm abduction respectively, which corresponds to 53%, 116% increase in muscle stiffness when scanning arm abducted from 30° to 45° and 60° (p < .001). After applying cushion support, shear moduli dropped to 24.04 ± 5.60 kPa, 31.98 ± 6.06 kPa, 37.47 ± 5.61 kPa for arm abducted to 30°, 45°, and 60° respectively (p < .001). The muscle stiffnesses between 30° abduction without support and 60° abduction with support had no significant difference (p > .05).

CONCLUSIONS

Muscle stiffness of supraspinatus increased with increasing arm abduction angle during ultrasound scanning. Utilizing cushion support underneath the arm was effective in reducing muscle stiffness in supraspinatus. Our results provide scientific justification on postural modifications for sonographers.

摘要

目的

在超声检查中,与工作相关的肌肉骨骼疾病的发病率仍然很高。本研究的目的是确定不同手臂外展角度下肌肉僵硬的变化,并研究在超声医师以不同角度外展手臂进行扫描时,使用衬垫支撑对减少冈上肌肌肉负荷的影响。

方法

这是一项前瞻性的交叉研究。纳入了 23 名年龄在 20 到 23 岁之间的健康女性受试者。要求受试者模拟进行标准的腹部超声检查。使用剪切波弹性成像评估在休息时以及在 30°、45°和 60°手臂外展角度下使用和不使用衬垫支撑时冈上肌的肌肉僵硬变化,作为剪切模量。使用泡沫塑料作为衬垫支撑。

结果

在休息时,冈上肌的平均剪切模量为 27.77 ± 5.84 kPa,在手臂外展 30°、45°和 60°时分别为 41.63 ± 7.09 kPa、63.88 ± 14.43 kPa 和 89.76 ± 16.55 kPa,这对应于从 30°到 45°和 60°手臂外展时肌肉僵硬度增加了 53%和 116%(p < 0.001)。使用衬垫支撑后,手臂外展 30°、45°和 60°时的剪切模量分别降至 24.04 ± 5.60 kPa、31.98 ± 6.06 kPa 和 37.47 ± 5.61 kPa(p < 0.001)。在没有支撑的 30°外展和有支撑的 60°外展之间,肌肉僵硬度没有显著差异(p > 0.05)。

结论

在超声扫描过程中,冈上肌的肌肉僵硬度随着手臂外展角度的增加而增加。在手臂下方使用衬垫支撑可有效降低冈上肌的肌肉僵硬度。我们的结果为超声医师的姿势调整提供了科学依据。