Suppr超能文献

基于亚甲基蓝嵌入锆的有机骨架被铝触发的“点亮”作用,用于提高双信号侧向流动免疫层析分析中大肠杆菌 O157:H7 分析的灵敏度。

"Lighting-up" methylene blue-embedded zirconium based organic framework triggered by Al for advancing the sensitivity of E. coli O157:H7 analysis in dual-signal lateral flow immunochromatographic assay.

机构信息

College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.

College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.

出版信息

J Hazard Mater. 2022 Mar 5;425:128034. doi: 10.1016/j.jhazmat.2021.128034. Epub 2021 Dec 8.

Abstract

The sensitive detection of foodborne pathogens is of great significance for ensuring food safety and quality. Herein, on the basis of methylene blue-embedded zirconium based organic framework (UIO@MB) as the remarkable capture carrier and signal indicator, with the Al-assisted the fluorescent signal response, we developed a label-free and dual-signal lateral flow immunochromatographic assay (LDLFIA) for sensitive detection of Escherichia coli (E. coli) O157:H7. The UIO@MB sensing carrier without monoclonal antibodies (mAbs) was manufactured, which adhered to bacteria to form the UIO@MB-E. coli O157:H7 conjugate, resulting in visible blue band. Then the fluorescent response of the OH-rich UIO@MB was excited by introducing Al, arising from capturing of Al by -OH through coordination and electrostatic affinity, thus generating a green fluorescent band. Impressively, a smartphone-based portable reading system was developed that can reflect the test results of UIO@MB-LDLFIA immediately. Under optimum conditions, UIO@MB-LDLFIA can complete colorimetric and fluorescent mode detection within 90 min, with a detection sensitivity of 10 CFU/mL, which were 100 times lower than traditional gold nanoparticles-based LFIA and polymerase chain reaction (PCR). Moreover, the feasibility of the method was further evaluated by the determination of E. coli O157: H7 in drinking water and cabbage with average recoveries of 85.1-123.0%.

摘要

食源性致病菌的灵敏检测对于确保食品安全和质量具有重要意义。在此,我们以嵌入亚甲基蓝的锆基有机骨架(UIO@MB)作为优异的捕获载体和信号指示剂,结合 Al 辅助的荧光信号响应,开发了一种无标记和双信号侧向流动免疫层析分析(LDLFIA)用于灵敏检测大肠杆菌(E. coli)O157:H7。制备了不含单克隆抗体(mAbs)的 UIO@MB 传感载体,其与细菌结合形成 UIO@MB-E. coli O157:H7 缀合物,导致可见的蓝色条带。然后,通过引入 Al 来激发富含 OH 的 UIO@MB 的荧光响应,这是由于 Al 通过配位和静电亲和力与-OH 结合而捕获的,从而产生绿色荧光条带。令人印象深刻的是,开发了一种基于智能手机的便携式读取系统,可以立即反映 UIO@MB-LDLFIA 的测试结果。在最佳条件下,UIO@MB-LDLFIA 可以在 90 分钟内完成比色和荧光模式检测,检测灵敏度为 10 CFU/mL,比传统的基于金纳米颗粒的 LFIA 和聚合酶链反应(PCR)低 100 倍。此外,还通过测定饮用水和白菜中的 E. coli O157:H7 进一步评估了该方法的可行性,平均回收率为 85.1-123.0%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验