Botti Giovanni, Botti Chiara, Ciancio Francesco
Aesthet Surg J. 2022 Apr 12;42(5):NP312-NP318. doi: 10.1093/asj/sjab422.
This retrospective study reports on the early experience of a private surgical center with Motiva Ergonomix SilkSurface breast implants.
The aim of this study was to examine the incidence of complications and satisfaction levels in women who received primary and revision breast augmentation or augmentation-mastopexy with Ergonomix SilkSurface breast implants.
A total of 356 consecutive patients received Ergonomix SilkSurface breast implants between April 2014 and October 2018 by 3 different surgeons and were followed-up for a minimum of 12 months. Complications were assessed by measuring the rate of rupture, capsular contracture, malposition, late seroma, double capsule, reoperation, symmastia, ptosis, extrusion, and infection. Satisfaction with aesthetic results was assessed on a Likert scale by both surgeon and patient.
Only 6 major complications were observed in these 356 patients (712 implants): 1 unilateral implant ptosis ("bottoming out") at 12 months (0.14%) and 2 capsular contractures (0.28%), 1 at 14 months and 1 at 2 years. At all time points, 98% of the patients were "extremely satisfied or very satisfied" with the aesthetic results, and the surgeons categorized the outcomes as "very important or important improvement" in 96% of the cases.
Motiva Ergonomix SilkSurface devices provided high patient satisfaction up to more than 5 years postoperatively with very few complications. These data are consistent with other reports in the literature. The observed favorable outcomes might be attributed, at least in part, to the bioengineered "cell-friendly" surface of these implants.
本回顾性研究报告了一家私立外科中心使用Motiva Ergonomix SilkSurface乳房植入物的早期经验。
本研究旨在调查接受初次及修复性隆乳术或隆乳-乳房上提术并使用Ergonomix SilkSurface乳房植入物的女性的并发症发生率和满意度。
2014年4月至2018年10月期间,共有356例连续患者由3位不同的外科医生植入了Ergonomix SilkSurface乳房植入物,并进行了至少12个月的随访。通过测量破裂率、包膜挛缩、位置异常、晚期血清肿、双包膜、再次手术、乳房融合、下垂、挤出和感染率来评估并发症。外科医生和患者均通过李克特量表评估对美学效果的满意度。
在这356例患者(712枚植入物)中仅观察到6例主要并发症:1例在12个月时出现单侧植入物下垂(“底部下垂”)(0.14%),2例包膜挛缩(0.28%),1例在14个月时出现,1例在2年时出现。在所有时间点,98%的患者对美学效果“极其满意或非常满意”,外科医生在96%的病例中将结果归类为“非常重要或重要改善”。
Motiva Ergonomix SilkSurface装置在术后5年以上为患者提供了高满意度,并发症极少。这些数据与文献中的其他报告一致。观察到的良好结果可能至少部分归因于这些植入物的生物工程“细胞友好型”表面。