Hong Pa, Kang Jae Kyoung, Hwang Seung Hwan, Lee Kyung Ah
Department of Radiology, Samsung Changwon Hospital, Sunkyunkwan University School of Medicine (SKKU-SOM), Changwon 51353, Republic of Korea.
Department of Plastic and Reconstructive Surgery, Jeju National University Hospital, Jeju 63241, Republic of Korea.
Gels. 2023 Mar 16;9(3):232. doi: 10.3390/gels9030232.
With the occurrence of breast implant crises in Korea, it has become increasingly important to detect complications earlier in patients receiving a device. We have therefore combined imaging modalities with an implant-based augmentation mammaplasty. In this study, we assessed the short-term treatment outcomes and safety of the Motiva Ergonomix Round SilkSurface (Establishment Labs Holdings Inc., Alajuela, Costa Rica) in Korean women. A total of 87 women ( = 87) were included in the current study. We compared preoperative anthropometric measurements between the right side and the left side of the breast. Moreover, we also compared the thickness of the skin, subcutaneous tissue and the pectoralis major measured on a breast ultrasound preoperatively and 3 months postoperatively. Furthermore, we analyzed the incidences of postoperative complications and the cumulative complication-free survival. Preoperatively, there was a significant difference in the distance from the nipple to the midline between the left and right side of the breast ( = 0.000). Both sides of the breast showed significant differences in the thickness of the pectoralis major preoperatively and 3 months postoperatively ( = 0.000). A total of 11 cases (12.6%) of postoperative complications occurred; these included five cases (5.7%) of early seroma, two cases (2.3%) of infection, two cases (2.3%) of rippling, one case (1.1%) of hematoma and one case (1.1%) of capsular contracture. Time-to-events were estimated at 386.68 ± 27.79 days (95% CI 334.11-439.27). Here, we describe our experience with imaging modalities in combination with the Motiva Ergonomix Round SilkSurface in Korean women.
随着韩国乳房植入危机的出现,对于接受该器械的患者更早地检测并发症变得越来越重要。因此,我们将成像模态与基于植入物的隆乳术相结合。在本研究中,我们评估了Motiva Ergonomix圆形丝面假体(艾立塑,Establishment Labs Holdings Inc.,阿拉胡埃拉,哥斯达黎加)在韩国女性中的短期治疗效果和安全性。本研究共纳入87名女性(n = 87)。我们比较了乳房左右两侧术前的人体测量数据。此外,我们还比较了术前和术后3个月乳房超声测量的皮肤、皮下组织和胸大肌的厚度。此外,我们分析了术后并发症的发生率和累积无并发症生存率。术前,乳房左右两侧从乳头到中线的距离存在显著差异(P = 0.000)。术前和术后3个月,乳房两侧胸大肌厚度均存在显著差异(P = 0.000)。共发生11例(12.6%)术后并发症;其中包括5例(5.7%)早期血清肿、2例(2.3%)感染、2例(2.3%)假体波动感、1例(1.1%)血肿和1例(1.1%)包膜挛缩。事件发生时间估计为386.68 ± 27.79天(95%置信区间334.11 - 439.27)。在此,我们描述了我们在韩国女性中将成像模态与Motiva Ergonomix圆形丝面假体相结合的经验。
J Plast Reconstr Aesthet Surg. 2023-5
Plast Reconstr Surg Glob Open. 2020-5-14
J Plast Reconstr Aesthet Surg. 2023-5
Plast Reconstr Surg. 2023-7-1
Aesthet Surg J. 2022-4-12