BACKGROUND

Root canal preparation with nickel-titanium (NiTi) instruments may lead to the formation of microcracks in the root canal wall. Vertical root fractures may initiate from dentinal cracks, and eventually necessitate tooth extraction.

OBJECTIVES

This study aimed to assess the effect of the instrumentation of curved root canals of mandibular molars with the 2Shape (2S) sequential rotary, EdgeFile® X1 (EFX1) reciprocating and NeoNiTi (NN) rotational single-file systems on the formation of dentinal microcracks with the use of micro-computed tomography (micro-CT).

MATERIAL AND METHODS

Thirty curved mandibular molar root canals were instrumented with the 2S, EFX1 and NN systems (10 in each group). The teeth underwent micro-CT before and after instrumentation. Next, the pre-instrumentation and post-instrumentation cross-sectional images were evaluated and compared for the detection of dentinal microcracks. The number of microcracks in each group was calculated and reported as percentage. The data was analyzed using the McNemar's test with the IBM SPSS Statistics for Windows software, v. 25.0 (α = 0.05).

RESULTS

Out of the 29,280 cross-sectional images evaluated in this study, 11.5% showed dentinal microcracks (n = 3,362). On the post-instrumentation images, the frequency percentage of microcracks was 12.0% (n = 585) in the 2S group, 8.8% (n = 402) in the EFX1 group and 13.3% (n = 694) in the NN group. All of the microcracks detected on the post-instrumentation images were also present on the preinstrumentation images and no new microcracks were formed after root canal instrumentation with the aforementioned systems.

CONCLUSIONS

Root canal instrumentation with the 2S, EFX1 and NN systems did not result in the formation of new dentinal microcracks.

摘要

背景

使用镍钛(NiTi)器械进行根管预备可能会导致根管壁形成微裂纹。垂直根裂可能起源于牙本质裂纹,并最终导致拔牙。

目的

本研究旨在评估 2Shape(2S)连续旋转、EdgeFile® X1(EFX1)往复和 NeoNiTi(NN)旋转单文件系统对下颌磨牙弯曲根管进行器械预备时,使用微计算机断层扫描(micro-CT)对牙本质微裂纹形成的影响。

材料和方法

用 2S、EFX1 和 NN 系统(每组 10 个)对 30 个弯曲下颌磨牙根管进行器械预备。牙齿在器械预备前后进行 micro-CT 检查。然后,评估并比较预备前后的横截面图像,以检测牙本质微裂纹。计算每组的微裂纹数量,并以百分比报告。使用 IBM SPSS Statistics for Windows 软件 v. 25.0(α = 0.05)进行数据的 McNemar 检验分析。

结果

在本研究中评估的 29,280 个横截面图像中,有 11.5%(n = 3,362)显示牙本质微裂纹。在器械预备后的图像中,2S 组微裂纹的频率百分比为 12.0%(n = 585),EFX1 组为 8.8%(n = 402),NN 组为 13.3%(n = 694)。在器械预备前后的图像上均能检测到所有微裂纹,并且在用上述系统进行根管预备后,没有形成新的微裂纹。

结论

用 2S、EFX1 和 NN 系统进行根管预备不会导致新的牙本质微裂纹形成。