Division of Nursing, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
Sci Rep. 2022 Jan 7;12(1):47. doi: 10.1038/s41598-021-03843-2.
The use of effective shielding materials against radiation is important among medical staff in nuclear medicine. Hence, the current study investigated the shielding effects of a commercially available tungsten apron using gamma ray measuring instruments. Further, the occupational radiation exposure of nurses during I-meta-iodo-benzyl-guanidine (I-MIBG) therapy for children with high-risk neuroblastoma was evaluated. Attachable tungsten shields in commercial tungsten aprons were set on a surface-ray source with I, which emit gamma rays. The mean shielding rate value was 0.1 ± 0.006 for I. The shielding effects of tungsten and lead aprons were evaluated using a scintillation detector. The shielding effect rates of lead and tungsten aprons against I was 6.3% ± 0.3% and 42.1% ± 0.2% at 50 cm; 6.1% ± 0.5% and 43.3% ± 0.3% at 1 m; and 6.4% ± 0.9% and 42.6% ± 0.6% at 2 m, respectively. Next, we assessed the occupational radiation exposure during I-MIBG therapy (administration dose: 666 MBq/kg, median age: 4 years). The total occupational radiation exposure dose per patient care per I-MIBG therapy session among nurses was 0.12 ± 0.07 mSv. The average daily radiation exposure dose per patient care among nurses was 0.03 ± 0.03 mSv. Tungsten aprons had efficient shielding effects against gamma rays and would be beneficial to reduce radiation exposures per patient care per I-MIBG therapy session.
医用核医学中,医护人员使用有效辐射屏蔽材料非常重要。因此,本研究采用伽马射线测量仪,对一种市售钨围裙的屏蔽效果进行了研究。此外,还评估了护士在对高危神经母细胞瘤儿童进行 I-间碘苄胍(I-MIBG)治疗期间的职业辐射暴露情况。在表面射线源 I 上安装了市售钨围裙的可附加钨屏蔽,I 会发射伽马射线。I 的平均屏蔽率为 0.1 ± 0.006。使用闪烁探测器评估了铅和钨围裙对 I 的屏蔽效果。在 50cm 处,铅和钨围裙对 I 的屏蔽效率分别为 6.3%±0.3%和 42.1%±0.2%;在 1m 处,分别为 6.1%±0.5%和 43.3%±0.3%;在 2m 处,分别为 6.4%±0.9%和 42.6%±0.6%。接下来,我们评估了 I-MIBG 治疗期间(给药剂量:666MBq/kg,中位年龄:4 岁)的职业辐射暴露情况。每位护士在一次 I-MIBG 治疗过程中的每位患者的职业辐射暴露剂量为 0.12 ± 0.07mSv。每位护士的平均日辐射暴露剂量为 0.03 ± 0.03mSv。钨围裙对伽马射线具有有效的屏蔽效果,有助于降低每位患者的 I-MIBG 治疗过程中的辐射暴露。