Suppr超能文献

基于3D打印技术的功能性适宜数字化全口义齿系统的评估

Evaluation of functional suitable digital complete denture system based on 3D printing technology.

作者信息

Deng Kehui, Chen Hu, Wang Yong, Zhou Yongsheng, Sun Yuchun

机构信息

Center of Digital Dentistry, Peking University School and Hospital of Stomatology, Beijing, China.

Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry, Beijing, China.

出版信息

J Adv Prosthodont. 2021 Dec;13(6):361-372. doi: 10.4047/jap.2021.13.6.361. Epub 2021 Dec 22.

Abstract

PURPOSE

To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done.

MATERIALS AND METHODS

Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients.

RESULTS

Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups.

CONCLUSION

FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

摘要

目的

为提高全口义齿的临床使用效果并简化其临床应用,提出了一种数字化全口义齿修复工作流程(功能性适配数字化全口义齿系统,FSD)并进行了初步临床评估。

材料与方法

招募了40名无牙颌患者,其中一半由一名口腔修复主任医师治疗,另一半由一名研究生治疗。根据首次就诊时获得的初印模和颌位关系,设计并打印诊断性义齿,以便在第二次就诊时获得最终印模、颌位关系和美学确认。重新设计的全口义齿作为模具打印出来,以制作最终义齿,并在第三次就诊时交付。为评估诊断性义齿所制取印模的准确性,以最终义齿为托盘制取印模,并采用三维比较分析两者差异。为评估FSD的临床效果,由牙医和患者确定视觉模拟评分(VAS)。

结果

义齿交付前减少了两次就诊。通过诊断性义齿制取的印模与最终义齿之间三维比较的均方根值在上颌为0.165±0.033mm,在下颌为0.139±0.031mm。主任医师组的VAS评分在8.5至9.6之间,而学生组在7.7至9.5之间;两组之间无统计学差异。

结论

FSD可简化全口义齿修复过程并减少就诊次数。诊断性义齿制取印模的准确性在临床上是可接受的。牙医和患者的VAS评分均令人满意。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5d5b/8712110/da3bbe1cf669/jap-13-361-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验