Suppr超能文献

新的肘部骨撞击症放射测量技术的可靠性。

Reliability of new radiographic measurement techniques for elbow bony impingement.

机构信息

Department of Orthopaedic Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia.

Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia.

出版信息

Radiol Oncol. 2022 Feb 11;56(1):32-36. doi: 10.2478/raon-2021-0056.

Abstract

BACKGROUND

Identifying the location and scale of radiographic changes in elbow bony impingement (EBI) is critical in formulating an appropriate diagnosis and treatment plan for such patients. The purpose of present study was to evaluate the intra-rater and inter-rater reliability of the new radiographic parameters, Anterior Impingement angle (AIa) and Posterior Impingement angle (PIa), for EBI. In addition, to determine if there was a relationship between radiographic parameters and clinical evaluation.

PATIENTS AND METHODS

Three raters of different levels of training evaluated the radiographs of 60 patients (30 in EBI group and 30 in normal group) twice, at least 2 weeks apart. Intra-rater and inter-rater reliabilities were calculated by Intraclass Correlation Coefficients (ICC) with 95% confidence intervals. Correlation between radiographic parameters and clinical evaluation was calculated by Pearson correlation coefficient.

RESULTS

In both groups, intra-rater and inter-rater reliabilities were substantial. There were no significant differences in reliability between upper-hand expert surgeons and resident for either measurement. Good correlation was observed between impingement arcs and range of motion values.

CONCLUSIONS

Both AIa and PIa measurements demonstrated substantial intra-rater and inter-rater reliability for normal radiographs and in EBI patients. Good reliability, for either expert surgeons or residents in training, and good correlation between radiographic measurements and manual testing, appoints this method may be easily and reliably used in every day practice.

摘要

背景

在制定肘部骨撞击症(EBI)患者的适当诊断和治疗计划时,确定 X 线摄影变化的位置和程度至关重要。本研究旨在评估新的 X 线摄影参数(前撞击角(AIa)和后撞击角(PIa))用于 EBI 的内部和外部观察者的可靠性。此外,还确定了影像学参数与临床评估之间是否存在关系。

患者和方法

3 名不同培训水平的观察者至少相隔 2 周对 60 名患者(EBI 组 30 名,正常组 30 名)的 X 线片进行了两次评估。采用 95%置信区间的组内相关系数(ICC)计算内部和外部观察者的可靠性。通过 Pearson 相关系数计算影像学参数与临床评估之间的相关性。

结果

在两组中,内部和外部观察者的可靠性均较高。两种测量方法在上手专家外科医生和住院医师之间的可靠性均无显著差异。撞击弧和活动范围值之间存在良好的相关性。

结论

AIa 和 PIa 测量值在正常 X 线片和 EBI 患者中均表现出较高的内部和外部观察者可靠性。无论是专家外科医生还是培训中的住院医师,其可靠性都较高,影像学测量值与手动测试之间的相关性也较好,这表明该方法在日常实践中易于且可靠地使用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9838/8884848/59f0e73fdbec/raon-56-032-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验