Department of Ophthalmology, Hatay Education and Research Hospital, Ekinci Mah. Cevreyolu Cad. Royals Park 13/1 No:23, Antakya, Hatay, Turkey.
Department of Ophthalmology, Adiyaman University Education and Research Hospital, Adiyaman, Turkey.
Aesthetic Plast Surg. 2022 Oct;46(5):2295-2300. doi: 10.1007/s00266-021-02756-9. Epub 2022 Jan 11.
To investigate the effects of blepharoplasty on intraocular pressure (IOP) and ocular biometric parameters.
A total of 112 eyelids of 56 patients undergoing bilateral blepharoplasty due to upper eyelid dermatochalasis was included. The patients were classified into three groups according to margin reflex distance (MRD) (Group 1 >4 mm MRD, Group 2 2-4 mm MRD, and Group 3 <2 mm MRD). The IOP and ocular biometric parameters obtained baseline and postoperative 3 month were compared.
The demographic characteristics of the groups were similar (p > 0.05, for all). IOP (p = 0.002) and central corneal thickness (p = 0.038) increased in Group 3. The mean amount of the increase in IOP was 0.95mmHg. The keratometric values increased in all groups and corneal astigmatism was also increased in Group 2 and Group 3 (p < 0.001, for all). The mean amount of the increase in corneal astigmatism was 0.54D in Group 3. Anterior chamber depth and axial length did not change (p > 0.05, for all). The intraocular lens powers calculated by six different formulas decreased in Group 3 (p < 0.001, for all), and the mean amount of the decrease was 0.40D.
Clinicians should be aware of the potential change in IOP and ocular biometric parameters in patients who underwent blepharoplasty. If a patient has glaucoma risk factors, close follow-up is needed after blepharoplasty. Change in strategy or timing may also be needed for dermatochalasis patients when planning corneal refractive surgery or cataract surgery.
This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
研究上睑皮肤松弛矫正术对眼压(IOP)和眼生物测量参数的影响。
纳入 56 例(112 只眼)因上睑皮肤松弛症行双侧上睑皮肤松弛矫正术的患者。根据睑缘退缩距离(MRD)将患者分为三组(MRD>4mm 为第 1 组,MRD 为 2-4mm 为第 2 组,MRD<2mm 为第 3 组)。比较患者术前和术后 3 个月的眼压和眼生物测量参数。
三组患者的一般资料差异无统计学意义(均为 P>0.05)。第 3 组患者的眼压(P=0.002)和中央角膜厚度(P=0.038)升高。眼压升高的平均幅度为 0.95mmHg。所有组的角膜曲率值均升高,第 2 组和第 3 组的角膜散光也增加(均为 P<0.001)。第 3 组角膜散光的平均增加幅度为 0.54D。前房深度和眼轴长度均无变化(均为 P>0.05)。第 3 组患者的 6 种不同计算公式计算得出的人工晶状体度数均降低(均为 P<0.001),平均降低幅度为 0.40D。
行上睑皮肤松弛矫正术的患者,临床医生应注意眼压和眼生物测量参数的潜在变化。如果患者有青光眼的危险因素,上睑皮肤松弛矫正术后需要密切随访。对于计划行角膜屈光手术或白内障手术的皮肤松弛症患者,可能需要改变策略或手术时机。
证据等级 IV:本杂志要求作者为每篇文章分配一个证据等级。如需详细了解这些基于证据的医学分级,请参考目录或在线作者指南 www.springer.com/00266。