Dent Mater J. 2022 May 31;41(3):363-367. doi: 10.4012/dmj.2021-236. Epub 2022 Jan 29.
This study evaluated the 3-dimensional (3D) fit of self-glazed zirconia monolithic crowns fabricated by wet deposition, in comparison with milled zirconia and lithium disilicate monolithic crowns. Dual-scan protocol was used to assess the fit of crowns. Root mean squares (RMS) and uniformity index (UI) were calculated to describe the gap size and uniformity. The self-glazed zirconia crowns had significantly lower RMS values for the gaps at axial wall and transition regions than the milled zirconia crowns, and for the gaps at occlusal region than both milled crowns. All 3 types of crowns had comparable RMS values for the gaps at marginal and chamfer regions and comparable UI values for both marginal and internal gaps. The 3D fit of the self-glazed zirconia monolithic crowns was clinically acceptable and they exhibited better fit at occlusal region than the milled crowns.