Diagn Microbiol Infect Dis. 2022 Apr;102(4):115637. doi: 10.1016/j.diagmicrobio.2022.115637. Epub 2022 Jan 16.
Patients in need of urgent inpatient treatment were recruited prospectively. A rapid point of care polymerase chain reaction test (POC-PCR; Liat®) for SARS-CoV2 was conducted in the Emergency Department (ED) and a second PCR-test from the same swab was ordered in the central laboratory (PCR). POC-PCR analyzers were digitally integrated in the laboratory information system. Overall, 160 ED patients were included. A valid POC-PCR-test result was available in 96.3% (n = 154) of patients. N = 16 patients tested positive for Severe Acute Respiratory Syndrome-Corona Virus 2 (10.0%). The POC PCR test results were available within 102 minutes (median, interquartile range: 56-211), which was significantly earlier compared to the central laboratory PCR (811 minutes; interquartile range: 533-1289, P < 0.001). The diagnostic accuracy of the POC-PCR test was 100%. The implementation and digital laboratory information system integration was successfully done. Staff satisfaction with the POC process was high. The POC-PCR testing in the ED is feasible and shows a very high diagnostic performance. Trial registration: DRKS00019207.
前瞻性招募需要紧急住院治疗的患者。在急诊科(ED)进行 SARS-CoV2 的即时护理点聚合酶链反应检测(POC-PCR;Liat®),并在中央实验室(PCR)对同一拭子进行第二次 PCR 检测。POC-PCR 分析仪已在实验室信息系统中进行了数字化整合。共有 160 名 ED 患者入组。96.3%(n=154)的患者可获得有效 POC-PCR 检测结果。N=16 名患者检测出严重急性呼吸综合征冠状病毒 2 呈阳性(10.0%)。POC-PCR 检测结果可在 102 分钟内(中位数,四分位间距:56-211)获得,与中央实验室 PCR(811 分钟;四分位间距:533-1289)相比显著更早(P<0.001)。POC-PCR 检测的诊断准确性为 100%。已成功实施并实现了数字化实验室信息系统集成。工作人员对 POC 流程的满意度很高。ED 中的 POC-PCR 检测是可行的,且具有非常高的诊断性能。试验注册:DRKS00019207。