Abstract

BACKGROUND

To evaluate and compare the changes in intraocular pressure and anterior eye segment biometrics during and after wearing two types of commonly used swimming goggles.

METHODS

In a cross-sectional study, a total of 40 healthy adults aged between 18 and 60 years old were selected to wear two kinds of common swimming goggles (ocular socket and orbital goggles). Intraocular pressure and anterior segment biometry were evaluated before wearing, at 2 and 5 min of wearing, and at 5 min after removing the goggles. Intraocular pressure (IOP), corneal front keratometry values (K1, K2, Km), central corneal thickness (CCT), central anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were measured.

RESULTS

The IOP at 2 min (21.0 ± 2.2 mmHg) and 5 min (21.2 ± 2.3 mmHg) was significantly higher than before wearing goggles (17.7 ± 2.1 mmHg). The IOP after the goggles were removed and at 5 min after the goggles were removed was 18.4 ± 2.3 mmHg and 17.7 ± 2.1 mmHg, respectively. ACV, ACD, and ACA values all decreased while the googles were worn. After the goggles were removed, these changes gradually returned to baseline values, with no significant difference in the values before and after.

CONCLUSION

This study proves that wearing orbital goggles can lead to an acute increase in IOP and a slight decrease in ACV, ACD, and ACA. However, once the goggles are removed, these indicators return to baseline levels, showing that wearing orbital goggles has no significant lasting effect on IOP and anterior segment parameters.

摘要

背景

评估和比较两种常用泳镜在佩戴和摘下期间及之后对眼内压和眼前节生物测量的影响。

方法

在一项横断面研究中,共选择了 40 名年龄在 18 至 60 岁之间的健康成年人,分别佩戴两种常见的游泳镜(眼眶镜和眶周镜)。在佩戴前、佩戴 2 分钟和 5 分钟以及摘下泳镜后 5 分钟时评估眼内压和眼前节生物测量值。测量眼内压(IOP)、角膜前表面角膜曲率值(K1、K2、Km)、中央角膜厚度(CCT)、中央前房深度(ACD)、前房容积(ACV)和前房角(ACA)。

结果

佩戴 2 分钟(21.0±2.2mmHg)和 5 分钟(21.2±2.3mmHg)时的 IOP 明显高于佩戴前(17.7±2.1mmHg)。摘下泳镜后 5 分钟时的 IOP 为 18.4±2.3mmHg,与佩戴前相比差异无统计学意义。佩戴泳镜期间,ACV、ACD 和 ACA 值均降低。摘下泳镜后,这些变化逐渐恢复至基线值,前后值差异无统计学意义。

结论

本研究证明佩戴眶周镜会导致眼内压急性升高和 ACV、ACD 和 ACA 轻微下降。但是,一旦摘下泳镜,这些指标会恢复至基线水平,表明佩戴眶周镜对眼内压和眼前节参数没有明显的持续影响。