O'Brodovich H, Coates G, Marrin M
J Appl Physiol (1985). 1986 May;60(5):1461-5. doi: 10.1152/jappl.1986.60.5.1461.
Experiments were performed to determine the effect of markedly negative pleural pressure (Ppl) or positive end-expiratory pressure (PEEP) on the pulmonary clearance (k) of technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). A submicronic aerosol containing 99mTc-DTPA was insufflated into the lungs of anesthetized intubated sheep. In six experiments k was 0.44 +/- 0.46% (SD)/min during the initial 30 min and was unchanged during the subsequent 30-min interval [k = 0.21 +/- 12%/min] when there was markedly increased inspiratory resistance. A 3-mm-diam orifice in the inspiratory tubing created the resistance. It resulted on average in a 13-cmH2O decrease in inspiratory Ppl. In eight additional experiments sheep were exposed to 2, 10, and 15 cmH2O PEEP (20 min at each level). During 2 cmH2O PEEP k = 0.47 +/- 0.15%/min, and clearance increased slightly at 10 cmH2O PEEP [0.76 +/- 0.28%/min, P less than 0.01]. When PEEP was increased to 15 cmH2O a marked increase in clearance occurred [k = 1.95 +/- 1.08%/min, P less than 0.001]. The experiments demonstrate that markedly negative inspiratory pressures do not accelerate the clearance of 99mTc-DTPA from normal lungs. The effect of PEEP on k is nonlinear, with large effects being seen only with very large increases in PEEP.
进行实验以确定显著的负压胸膜腔压力(Ppl)或呼气末正压(PEEP)对99m锝标记的二乙三胺五乙酸(99mTc-DTPA)肺清除率(k)的影响。将含有99mTc-DTPA的亚微米气溶胶吹入麻醉插管绵羊的肺中。在六个实验中,最初30分钟内k为0.44±0.46%(标准差)/分钟,在随后30分钟间隔内当吸气阻力显著增加时保持不变[k = 0.21±12%/分钟]。吸气管道中的一个3毫米直径的孔口产生阻力。这平均导致吸气Ppl降低13厘米水柱。在另外八个实验中,绵羊分别暴露于2、10和15厘米水柱的PEEP(每个水平持续20分钟)。在2厘米水柱PEEP时,k = 0.47±0.15%/分钟,在10厘米水柱PEEP时清除率略有增加[0.76±0.28%/分钟,P<0.01]。当PEEP增加到15厘米水柱时,清除率显著增加[k = 1.95±1.08%/分钟,P<0.001]。实验表明,显著的负吸气压力不会加速99mTc-DTPA从正常肺中的清除。PEEP对k的影响是非线性的,只有在PEEP非常大幅度增加时才会出现显著影响。