Diagnostics (Basel). 2022 Feb 11;12(2):459. doi: 10.3390/diagnostics12020459.
The purpose of the present study was to evaluate the value of full-field digital mammography (FFDM) and automated breast ultrasound (ABUS) in the diagnosis of breast cancer compared to FFDM associated with digital breast tomosynthesis (DBT). Methods: This retrospective study included 50 female patients with a denser framework of connective tissue fibers, characteristic of young women who underwent FFDM, DBT, handheld ultrasound (HHUS), and ABUS between January 2017 and October 2018. The sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and accuracy of FFDM+ABUS were 81.82% (95% CI [48.22-97.72]), 89.74% (95% CI [75.78-97.13]), 69.23% (95% CI [46.05-85.57]), 94.59% (95% CI [83.26-98.40]), and 88% (95% CI [75.69-95.47]), while for FFDM+DBT, the values were as follows: 91.67% (95% CI [61.52-99.79]), 71.79% (95% CI [55.13-85.00]), 50% (95% CI [37.08-62.92]), 96.55% (95% CI [80.93-99.46]), 76.47% (95% CI [62.51-87.21]). We found an almost perfect agreement between the two readers regarding FFDM associated with ABUS, and substantial agreement regarding FFDM+DBT, with a kappa coefficient of 0.896 and 0.8, respectively; < 0.001. Conclusions: ABUS and DBT are suitable as additional diagnostic imaging techniques to FFDM in women at an intermediate risk of developing breast cancer through the presence of dense breast tissue. In this study, DBT reduced the number of false negative results, while the use of ABUS resulted in an increase in specificity.
本研究的目的是评估全视野数字乳腺摄影(FFDM)和自动乳腺超声(ABUS)在乳腺癌诊断中的价值,并与FFDM联合数字乳腺断层合成(DBT)进行比较。方法:这项回顾性研究纳入了50例结缔组织纤维结构致密的女性患者,这些患者具有年轻女性的特征,于2017年1月至2018年10月期间接受了FFDM、DBT、手持超声(HHUS)和ABUS检查。FFDM + ABUS的敏感性(Se)、特异性(Sp)、阳性预测值(PPV)、阴性预测值(NPV)和准确性分别为81.82%(95%置信区间[48.22 - 97.72])、89.74%(95%置信区间[75.78 - 97.13])、69.23%(95%置信区间[46.05 - 85.57])、94.59%(95%置信区间[83.26 - 98.40])和88%(95%置信区间[75.69 - 95.47]),而FFDM + DBT的相应值如下:91.67%(95%置信区间[61.52 - 99.79])、71.79%(95%置信区间[55.13 - 85.00])、50%(95%置信区间[37.08 - 62.92])、96.55%(95%置信区间[80.93 - 99.46])、76.47%(95%置信区间[62.51 - 87.