使用小梁微结构分析比较锥形束计算机断层扫描和数字化全景X线摄影术检测种植体周围牙槽骨变化的情况。

Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis.

作者信息

Magat Guldane, Oncu Elif, Ozcan Sevgi, Orhan Kaan

机构信息

Department of Oral and Maxillofacial Radiology, Konya, Turkey.

Department of Periodontology, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey.

出版信息

J Korean Assoc Oral Maxillofac Surg. 2022 Feb 28;48(1):41-49. doi: 10.5125/jkaoms.2022.48.1.41.

Abstract

OBJECTIVES

We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative.

MATERIALS AND METHODS

In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants.

RESULTS

There were no significant differences between DPR and CBCT measurements of FD values (>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (>0.05). GSVs were not correlated with FD values (>0.05).

CONCLUSION

The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the peri-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstructural parameters. Therefore, GSVs and FDs should be considered different parameters for assessing bone quality.

摘要

目的

我们比较了种植术后即刻及术后12个月时,数字化全景X线摄影(DPR)和锥形束计算机断层扫描(CBCT)上种植体周围牙槽骨的分形维数(FD)和灰度值(GSV)的变化。

材料与方法

在这项回顾性研究中,分析了16例接受下颌后牙区牙种植体植入的患者,这些患者在植入后约2周及植入后1年进行了CBCT扫描。为每位患者选择一个感兴趣区域。在种植术后即刻及12个月随访时评估FD和GSV,以检查种植体的功能负荷。

结果

DPR和CBCT测量的FD值之间无显著差异(>0.05)。种植术后即刻及12个月随访时计算的FD值和GSV之间未观察到显著差异(>0.05)。GSV与FD值不相关(>0.05)。

结论

DPR和重建的全景CBCT图像在评估FD方面表现出相似的图像质量。与种植术后即刻的值相比,在种植体功能负荷的术后12个月评估中,种植体周围小梁骨结构的FD值或GSV没有变化。代表骨量的GSV与预测骨微观结构参数的FD值不一致。因此,GSV和FD应被视为评估骨质量的不同参数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0575/8890962/69177761659a/jkaoms-48-1-41-f1.jpg