Abstract

BACKGROUND

For a better assessment of thyroid function, each laboratory should establish its own reference intervals (RI). In Lebanon, no previous study has been conducted to establish the reference values for thyroid function tests.

METHODS

This cross-sectional study included 301 volunteers aged between 18 and 65 years (65.8% women, 34.2% men), free from any thyroid pathology and any condition that could affect thyroid function tests. The reference intervals of thyroid-stimulating hormone (TSH), free T4 (FT4), free T3 (FT3), and total T3 (TT3) were measured on the Roche Cobas e411 machine. 39 subjects tested positive for thyroid peroxidase antibodies (TPOAb) and/or thyroglobulin antibodies (TGAb), were excluded from the study.

RESULTS

There was an increase in the 2.5 percentile for the TSH compared to the value provided by the manufacturer (from 0.27 to 0.53 mlU/L) as well as a decrease in the 97.5 percentile for the FT4, TT3, and FT3 (respectively, from 22 to 19.78 pmol/L for FT4, from 3.1 to 2.71 nmol/L for TT3, and from 6.80 to 6.10 pmol/L for FT3). Higher TT3 and FT3 values were noted in men compared to women (respectively, = 0.068 and < 0.0001). An age decrease in FT4 and FT3 was also observed (respectively, = 0.045 and < 0.0001).

CONCLUSION

The established RI of thyroid function tests for the Lebanese population were significantly different from the values recommended by the manufacturer (Roche Diagnostics). Changing our RI values will allow a more accurate diagnosis of thyroid dysfunction.

摘要

背景

为了更好地评估甲状腺功能,每个实验室都应建立自己的参考区间(RI)。在黎巴嫩,此前尚未开展过确定甲状腺功能测试参考值的研究。

方法

这项横断面研究纳入了301名年龄在18至65岁之间的志愿者(65.8%为女性,34.2%为男性),他们没有任何甲状腺疾病以及任何可能影响甲状腺功能测试的情况。在罗氏Cobas e411仪器上测量促甲状腺激素(TSH)、游离T4(FT4)、游离T3(FT3)和总T3(TT3)的参考区间。39名甲状腺过氧化物酶抗体(TPOAb)和/或甲状腺球蛋白抗体(TGAb)检测呈阳性的受试者被排除在研究之外。

结果

与制造商提供的值相比,TSH的第2.5百分位数有所增加(从0.27增至0.53 mIU/L),同时FT4、TT3和FT3的第97.5百分位数有所下降(FT4分别从22降至19.78 pmol/L,TT3从3.1降至2.71 nmol/L,FT3从6.80降至6.10 pmol/L)。与女性相比,男性的TT3和FT3值更高(分别为P = 0.068和P < 0.0001)。还观察到FT4和FT3随年龄下降(分别为P = 0.045和P < 0.0001)。

结论

为黎巴嫩人群建立的甲状腺功能测试RI与制造商(罗氏诊断公司)推荐的值有显著差异。改变我们的RI值将有助于更准确地诊断甲状腺功能障碍。