基于纸的流动传感器,用于通过聚合物溶液中酶水解诱导的粘度变化来检测透明质酸酶。

Paper-Based Flow Sensor for the Detection of Hyaluronidase via an Enzyme Hydrolysis-Induced Viscosity Change in a Polymer Solution.

机构信息

School of Pharmaceutical Sciences, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250014, China.

Key Laboratory of Colloid and Interface Chemistry, Ministry of Education, Shandong University, Jinan 250100, China.

出版信息

Anal Chem. 2022 Mar 22;94(11):4643-4649. doi: 10.1021/acs.analchem.1c04552. Epub 2022 Mar 8.

Abstract

Hyaluronidase (HAase) is implicated in inflammation, cancer development, and allergic reaction. The detection of HAase is significantly important in clinical diagnosis and medical treatment. Herein, we propose a new principle for the development of equipment-free and label-free paper-based flow sensors based on the enzymatic hydrolysis-induced viscosity change in a stimuli-responsive polymer solution, which increases the water flow distance on the pH indicator paper. The detection of HAase is demonstrated as an example. This facile and versatile method can overcome the potential drawbacks of traditional hydrogel-based sensors, including complex preparation steps, slow response time, or low sensitivity. Moreover, it can also avoid the use of specialized instruments, labeled molecules, or functionalized nanoparticles in the sensors developed using the polymer solutions. Using this strategy, the detection of HAase is achieved with a limit of detection as low as 0.2 U/mL. Also, it works well in human urine. Additionally, the detection of tannic acid, which is an inhibitor of HAase, is also fulfilled. Overall, a simple, efficient, high-throughput, and low-cost detection method is developed for the rapid and quantitative detection of HAase and its inhibitor without the use of labeled molecules, synthetic particles, and specialized instruments. As only minimal reagents of HAase, HA, and paper are used, it is very promising in the development of commercial kits for point-of-care testing.

摘要

透明质酸酶(HAase)与炎症、癌症发展和过敏反应有关。HAase 的检测在临床诊断和治疗中具有重要意义。本文提出了一种新的基于刺激响应聚合物溶液中酶解诱导的粘度变化的无设备和无标记纸基流动传感器的开发原理,该原理增加了 pH 指示剂纸上的水流距离。以 HAase 的检测为例进行了演示。这种简单而通用的方法可以克服传统水凝胶基传感器的潜在缺点,包括复杂的制备步骤、较慢的响应时间或较低的灵敏度。此外,它还可以避免在使用聚合物溶液开发的传感器中使用专用仪器、标记分子或功能化纳米粒子。使用该策略,HAase 的检测限低至 0.2 U/mL。此外,它在人尿中也能很好地工作。此外,还实现了对 HAase 抑制剂单宁酸的检测。总之,开发了一种简单、高效、高通量且低成本的检测方法,用于快速定量检测 HAase 及其抑制剂,而无需使用标记分子、合成颗粒和专用仪器。由于仅使用了最小量的 HAase、HA 和纸张作为试剂,因此非常有希望开发用于即时护理测试的商业试剂盒。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验