J Refract Surg. 2022 Mar;38(3):158-166. doi: 10.3928/1081597X-20211220-01. Epub 2022 Mar 1.
To compare the objective and subjective outcomes between the extended depth of focus (EDOF) Mini Well intraocular lens (IOL) and the aspheric monofocal Mini-4-Ready IOL (both SIFI S.p.A.) in patients with high myopia.
In this prospective comparative study, 40 patients with high myopia (axial length ≥ 26 mm) were enrolled: 20 patients were bilaterally implanted with the EDOF Mini Well IOL (EDOF group) and 20 patients were bilaterally implanted with the Mini-4-Ready IOL (monofocal group). Three-month follow-up data included corrected and uncorrected distance visual acuity at 4 m and 80, 67, and 40 cm, defocus curves, subjective and objective contrast sensitivity, objective optical quality (calculated with Optical Quality Analysis System; Visiometrics SL), halometry, and reading performance. Subjective visual quality was evaluated with National Eye Institute Refractive Error Quality of Life Instrument 42 scores.
All visual acuities were significantly better in the EDOF group ( ⩽ .04) except monocular and binocular uncorrected and corrected distance visual acuities for distance ( ≥ .50). Defocus curves for myopic and hyperopic values were better in the EDOF group ( ⩽ .05), apart from +0.50 to -0.50 D ( ≥ .16). Contrast sensitivity curves was worse in the EDOF group in the mesopic-with-glare condition ( ⩽ .04). No differences were found in halometric values ( ≥ .15) and OQAS outcomes ( ≥ .47). National Eye Institute Refractive Error Quality of Life Instrument 42 subscale scores were better for expectation, near vision, activity limitations, and dependence on correction in the EDOF group ( ⩽ .04).
Intermediate and near visual acuities were better in the EDOF group than in the monofocal group, with a comparable visual quality index between groups. .
比较扩展景深(EDOF)Mini Well 人工晶状体(IOL)和非球面单焦点 Mini-4-Ready IOL(均为 SIFI S.p.A.)在高度近视患者中的客观和主观结果。
在这项前瞻性对照研究中,纳入了 40 名高度近视患者(眼轴长度≥26mm):20 名患者双侧植入 EDOF Mini Well IOL(EDOF 组),20 名患者双侧植入 Mini-4-Ready IOL(单焦点组)。3 个月随访数据包括 4m 和 80、67、40cm 的矫正和未矫正远视力、离焦曲线、主观和客观对比敏感度、客观光质量(用光学质量分析系统计算;Visiometrics SL)、眼压测量和阅读性能。使用国家眼科研究所屈光不正生活质量 42 项量表评估主观视觉质量。
除了距离的单眼和双眼未矫正和矫正远视力(≥0.50)外,EDOF 组的所有视力均明显更好( ⩽.04)。在 EDOF 组中,近视和远视值的离焦曲线更好( ⩽.05),除了+0.50 至-0.50 D( ⩾.16)。在明适应眩光条件下,EDOF 组的对比敏感度曲线更差( ⩽.04)。在眼压测量值( ⩾.15)和 OQAS 结果( ⩾.47)方面无差异。EDOF 组的期望、近视力、活动受限和对矫正的依赖的国家眼科研究所屈光不正生活质量 42 项量表评分更好( ⩽.04)。
EDOF 组的中距离和近距离视力优于单焦点组,两组之间的视觉质量指数相当。