Suppr超能文献

精英现代五项全能运动员心率变异性的符号分析及其在交感神经刺激期间变化的可靠性:一项初步研究

Reliability of Symbolic Analysis of Heart Rate Variability and Its Changes During Sympathetic Stimulation in Elite Modern Pentathlon Athletes: A Pilot Study.

作者信息

Gąsior Jakub S, Rosoł Maciej, Młyńczak Marcel, Flatt Andrew A, Hoffmann Bartosz, Baranowski Rafał, Werner Bożena

机构信息

Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, Warsaw, Poland.

Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland.

出版信息

Front Physiol. 2022 Feb 28;13:829887. doi: 10.3389/fphys.2022.829887. eCollection 2022.

Abstract

BACKGROUND AND PURPOSE

Most studies on heart rate variability (HRV) in professional athletes concerned linear, time-, and frequency-domain indices, and there is lack of studies on non-linear parameters in this group. The study aimed to determine the inter-day reliability, and group-related and individual changes of short-term symbolic dynamics (SymDyn) measures during sympathetic nervous system activity (SNSa) stimulation among elite modern pentathletes.

METHODS

Short-term electrocardiographic recordings were performed in stable measurement conditions with a 7-day interval between tests. SNSa stimulation isometric handgrip strength test was conducted on the second day of study. The occurrence rate of patterns without variations (0V), with one variation (1V), two like (2LV), and two unlike variations (2UV) obtained using three approaches (the Max-min, the , and the Equal-probability methods) were analyzed. Relative and absolute reliability were evaluated.

RESULTS

All SymDyn indices obtained using the Max-min method, 0V, and 2UV obtained using the method, 2UV obtained using the Equal-probability method presented acceptable inter-day reliability (the intraclass correlation coefficient between .91 and .99, Cohen's between -.08 and .10, the within-subject coefficient of variation between 4% and 22%). 2LV, 2UV, and 0V obtained using the Max-min and methods significantly decreased and increased, respectively, during SNSa stimulation-such changes were noted for all athletes. There was no significant association between differences in SymDyn parameters and respiratory rate in stable conditions and while comparing stable conditions and SNSa stimulation.

CONCLUSION

SymDyn indices may be used as reliable non-respiratory-associated parameters in laboratory settings to detect autonomic nervous system (ANS) activity modulations in elite endurance athletes. These findings provide a potential solution for addressing the confounding influence of respiration frequency on HRV-derived inferences of cardiac autonomic function. For this reason, SymDyn may prove to be preferable for field-based monitoring where measurements are unsupervised.

摘要

背景与目的

大多数关于职业运动员心率变异性(HRV)的研究关注线性、时域和频域指标,而该群体中关于非线性参数的研究较少。本研究旨在确定精英现代五项全能运动员在交感神经系统活动(SNSa)刺激期间短期符号动力学(SymDyn)测量的日间可靠性、与组相关的变化以及个体变化。

方法

在稳定的测量条件下进行短期心电图记录,两次测试间隔7天。在研究的第二天进行SNSa刺激——等长握力测试。分析使用三种方法(最大-最小法、[此处原文缺失具体方法名称]法和等概率法)获得的无变化模式(0V)、有一个变化模式(1V)、两个相似变化模式(2LV)和两个不同变化模式(2UV)的发生率。评估相对可靠性和绝对可靠性。

结果

使用最大-最小法获得的所有SymDyn指标、使用[此处原文缺失具体方法名称]法获得的0V和2UV、使用等概率法获得的2UV呈现出可接受的日间可靠性(组内相关系数在0.91至0.99之间,科恩系数在-0.08至0.10之间,受试者内变异系数在4%至22%之间)。在SNSa刺激期间,使用最大-最小法和[此处原文缺失具体方法名称]法获得的2LV、2UV和0V分别显著降低和增加——所有运动员均出现此类变化。在稳定条件下以及比较稳定条件和SNSa刺激时,SymDyn参数差异与呼吸频率之间无显著关联。

结论

在实验室环境中,SymDyn指标可作为可靠的非呼吸相关参数,用于检测精英耐力运动员自主神经系统(ANS)活动的调制。这些发现为解决呼吸频率对基于HRV的心脏自主功能推断的混杂影响提供了一种潜在解决方案。因此,SymDyn可能被证明更适合在无监督测量的现场监测中使用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/bc5f/8918944/bc444299fa0f/fphys-13-829887-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验