Division of Cardiovascular Medicine, Department of Medicine, University of Pennsylvania and Perelman School of Medicine. This author takes responsibility for all aspects of the reliability and freedom from bias of the data presented and their discussed interpretation. 3400 Civic Center Blvd., Philadelphia, PA 19104, USA.
Kaiser Permanente South Sacramento Medical Center. Division of Cardiovascular Medicine, Department of Medicine, This author takes responsibility for study design, data collection, and a critical revision of the manuscript. 6600 Bruceville Road, Sacramento, CA 95823, USA.
Int J Cardiol Heart Vasc. 2022 Mar 11;39:100993. doi: 10.1016/j.ijcha.2022.100993. eCollection 2022 Apr.
Cardiac point of care ultrasound (POCUS) is increasingly utilized by trainees across various specialties and can rapidly assess the cardiac status of unstable patients. However, the quality of trainee performed cardiac examinations has been reported only in controlled studies. In this study we aimed to assess the quality of all cardiac POCUS performed by internal medicine trainees at a major academic medical center over a three-year period.
256 studies were included and were graded by experts blinded to postgraduate year (PGY) using a previously validated scoring metric.
We found significant improvement in overall quality of resident performed cardiac POCUS from PGY 1 to 3 (10.8, 10.2, 13.2, p = 0.012). Assessment of left ventricular function was possible in 82% of studies and increased from PGY 1 to PGY 3 (77%, 76%, 88%, p = 0.025). Similar trends were seen in the assessment of the pericardial space (67%, 71%, 84%, p = 0.012). Images sufficient for right ventricular and volume status assessment were less commonly found (65%, 60%, 75% and 60%, 49%, 57%, respectively).
This study provides a real world experience of the level of diagnostic accuracy that can be expected from IM trainees with minimal hands-on supervision.
心脏即时超声检查(POCUS)在各个专业的实习生中越来越多地被使用,并且可以快速评估不稳定患者的心脏状况。然而,仅在对照研究中报告了实习生进行心脏检查的质量。在本研究中,我们旨在评估一所主要学术医疗中心的内科实习生在三年期间进行的所有心脏POCUS检查的质量。
纳入256项研究,并由对研究生年级(PGY)不知情的专家使用先前验证的评分指标进行分级。
我们发现住院医师进行心脏POCUS检查的总体质量从PGY 1到PGY 3有显著提高(10.8、10.2、13.2,p = 0.012)。82%的研究能够评估左心室功能,且从PGY 1到PGY 3有所增加(77%、76%、88%,p = 0.025)。在心包腔评估方面也观察到类似趋势(67%、71%、84%,p = 0.012)。足以评估右心室和容量状态的图像较少见(分别为65%、60%、75%和60%、49%、57%)。
本研究提供了在最少实践监督下内科实习生预期诊断准确性水平的真实世界经验。