A quantitative, high throughput, fully automated diagnostic method for the detection of neutralizing anti-SARS-CoV-2 antibodies was developed on the Phadia system based on the interaction of SARS-CoV-2 S1 protein and the human ACE-2 receptor. This method was compared to the current state of the art plaque reduction neutralization test (PRNT) and a high correlation between the two methods was observed. Using a large cohort of blood samples from convalescent patients and controls the method displays very high sensitivity and specificity (99,8% and 99.99%, respectively). Neutralizing antibody titers of mRNA-1273 and BNT162b2-vaccinated persons can also be quantified with this method as well. This fully automated method provides the possibility to determine anti-SARS-CoV-2 neutralizing antibody concentrations in just 2 h.
基于 Phadia 系统,我们开发了一种定量、高通量、全自动的诊断方法,用于检测中和抗 SARS-CoV-2 抗体,该方法基于 SARS-CoV-2 S1 蛋白与人类 ACE-2 受体的相互作用。将该方法与目前的病毒中和试验(PRNT)进行了比较,观察到两种方法之间具有高度相关性。使用来自康复期患者和对照者的大样本血液队列,该方法显示出非常高的灵敏度和特异性(分别为 99.8%和 99.99%)。该方法还可以定量检测 mRNA-1273 和 BNT162b2 疫苗接种者的中和抗体滴度。这种全自动方法可在 2 小时内测定 SARS-CoV-2 中和抗体浓度。