Abstract

AIM AND OBJECTIVE

To assess and compare the dislodging force of double crown-retained removable partial dentures (RPDs) made from polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) at insertion (baseline) and one year after clinical functional use.

MATERIALS AND METHODS

A total of 18 patients with maxillary symmetrical Kennedy class I with the second premolars being the last standing abutment were selected. The patients were randomly assigned into two groups according to the materials used for the construction of the double crown-retained RPD. Group I: Double crown-retained RPDs were made from PEKK. Group II: Double crown-retained RPDs were made from PEEK. For both groups, the primary copings were made from zirconia (ZrO). The dislodging force was measured using a digital force gauge at baseline and one year after clinical functional use. An independent -test was used for intergroup comparisons and a paired -test for intragroup comparisons.

RESULTS

when comparing both groups at baseline, there was no significant difference between the two groups, but after one year, Group I had a significantly higher dislodging force value than Group II. Individually, there was an increase in dislodging force in both groups one year after clinical functional use, which was statistically significant for Group I.

CONCLUSION

After clinical functional use, double crown-retained RPDs made from PEEK in combination with ZrO primary copings demonstrate a minimal increase in dislodging force, while those made of PEKK demonstrate a significant increase in dislodging force.

CLINICAL SIGNIFICANCE

All patients were satisfied with the retention and esthetics of their dentures. Polyetherketoneketone double crown-retained RPDs demonstrate better retention one year after clinical functional use.

摘要

目的

评估并比较由聚醚酮酮(PEKK)和聚醚醚酮(PEEK)制成的双冠固位可摘局部义齿(RPD)在插入时(基线)及临床功能使用一年后的脱位力。

材料与方法

选取18例上颌对称性肯氏I类患者,第二前磨牙为最后剩余基牙。根据制作双冠固位RPD所用材料将患者随机分为两组。第一组:双冠固位RPD由PEKK制成。第二组:双冠固位RPD由PEEK制成。两组的基台帽均由氧化锆(ZrO)制成。在基线时及临床功能使用一年后,使用数字测力计测量脱位力。组间比较采用独立样本t检验,组内比较采用配对t检验。

结果

在基线时比较两组,两组之间无显著差异,但一年后,第一组的脱位力值显著高于第二组。单独来看,两组在临床功能使用一年后脱位力均有所增加,第一组具有统计学意义。

结论

临床功能使用后,由PEEK与ZrO基台帽组合制成的双冠固位RPD脱位力增加最小,而由PEKK制成的脱位力显著增加。

临床意义

所有患者对其义齿的固位和美观均满意。聚醚酮酮双冠固位RPD在临床功能使用一年后显示出更好的固位效果。