Suppr超能文献

青光眼患者行小梁微旁路支架植入联合白内障手术后的散光型人工晶状体的屈光效果。

Refractive outcomes of toric intraocular lens in combined trabecular micro bypass stent implantation and cataract surgery in glaucomatous eyes.

机构信息

Clínica Rementería, c/ Almagro nº36, entreplanta dcha, 28010, Madrid, Spain.

Hospital Universitario Ramón y Cajal, Madrid, Spain.

出版信息

Int Ophthalmol. 2022 Sep;42(9):2711-2718. doi: 10.1007/s10792-022-02259-9. Epub 2022 Mar 30.

Abstract

PURPOSE

To evaluate the impact of trabecular micro bypass stents (iStent Inject) on refractive outcomes with toric intraocular lens (IOL) in glaucomatous eyes.

METHODS

We identified glaucomatous eyes receiving a toric IOL between October 2017 and December 2020. Eyes with iStent implantation were included in the study group and eyes undergoing isolated phacoemulsification served as controls. Corrected and uncorrected visual acuity, manifest refraction, intraocular pressure (IOP), and number of hypotensive drugs three months after surgery were evaluated.

RESULTS

26 eyes comprised the study group and 41 eyes the control group. Mean postoperative refractive cylinder was 0.26D in the control and 0.11D in the iStent group, with 63% and 85% of eyes with a cylinder of 0 and 85% and 92% of eyes with a cylinder ≤ 0.5D respectively. The mean absolute difference between target and outcome spherical equivalent was 0.26D in the control and 0.22D in the iStent group, with all eyes within 0.75D of target. LogMar uncorrected postoperative vision in eyes targeted for emmetropia was 0.04 in the control and 0.03 in the iStent group. There was a statistically significant reduction in IOP and number of hypotensive drugs in both groups, with a mean decrease in IOP of 8.6% in the control and 15.7% in the iStent group. The number of hypotensive drugs dropped from 1.63 ± 0.80 to 1.34 ± 0.91 in the control group and from 2.12 ± 0.65 to 0.44 ± 0.71 in the iStent group.

CONCLUSION

Toric IOLs provide predictable refractive outcomes in glaucomatous eyes undergoing combined phacoemulsification with iStent implantation, reducing postoperative spectacle dependence.

摘要

目的

评估小梁微旁路支架(iStent Inject)对青光眼患者行散光矫正型人工晶状体(IOL)植入术后屈光结果的影响。

方法

我们筛选了 2017 年 10 月至 2020 年 12 月间接受散光矫正型 IOL 植入的青光眼患者。将行 iStent 植入术的患者纳入研究组,行单纯超声乳化白内障吸除术的患者作为对照组。评估术后 3 个月时的矫正和未矫正视力、主观验光结果、眼压(IOP)和降眼压药物使用数量。

结果

研究组纳入 26 只眼,对照组纳入 41 只眼。对照组术后等效球镜平均为 0.26D,iStent 组为 0.11D,前者 63%和 85%的患者术后柱镜为 0 及 0.5D 以下,后者为 92%和 85%。对照组和 iStent 组的目标等效球镜与术后实际值的平均绝对差值分别为 0.26D 和 0.22D,两组所有患者的实际值均在目标值的 0.75D 以内。目标正视眼的术后未矫正 logMAR 视力,对照组为 0.04,iStent 组为 0.03。两组术后 IOP 和降眼压药物使用数量均显著降低,对照组 IOP 平均降低 8.6%,iStent 组降低 15.7%。对照组的降眼压药物使用数量从术前的 1.63±0.80 降至术后的 1.34±0.91,iStent 组从 2.12±0.65 降至术后的 0.44±0.71。

结论

在青光眼患者中行超声乳化白内障吸除术联合 iStent 植入,可提供预测性的屈光结果,减少术后对眼镜的依赖。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验