Suppr超能文献

腓骨头处腓总神经的剪切波弹性成像。

Shear wave elastography of the common fibular nerve at the fibular head.

机构信息

Department of Internal Medicine, College of Medicine, Prince Sattam Bin Abdulaziz University, Al-Kharj, Kingdom of Saudi Arabia,Department of Radiology, University of Missouri, Columbia, MO, USA,Department of Medicine, College of Medicine, Al Imam Mohammed Ibn Saud Islamic University, Riyadh, Kingdom of Saudi Arabia,Neurology Department, College of Medicine, Prince Sattam Bin Abdulaziz University, Al-Kharj, Kingdom of Saudi Arabia,Neurology Department, Faculty of Medicine, Minia University, Minia, Egypt.

出版信息

Medicine (Baltimore). 2022 Mar 18;101(11). doi: 10.1097/MD.0000000000029052.

Abstract

The aim of this work is to study the sonoelastographic features of the common fibular nerve in healthy adult subjects.This is an observational cross-sectional study. Shear wave elastography was used to evaluate the common fibular nerve. Crosssectional area and stiffness were measured in kilopascal (kPa) and meters/second (m/s).The study included 82 common fibular nerves in 41 healthy adult subjects. The mean cross-sectional area of the common fibular nerve at the fibular head was 8.7 mm2. Positive correlation was noted between stiffness measurements between short and long axes by both methods. The mean stiffness of the common fibular nerve in the short axis was 22.5 kPa, and in the long axis (LA) was 35.4 kPa. Positive correlation was noted between height and stiffness measured by both methods in both axes by kPa. In m/s, the mean stiffness of the common fibular in the short axis was 2.6 m/s, and while in the LA was 3.4 m/s. Height showed positive correlation with both axes for stiff measurements in m\s. Weight showed positive correlation with stiffness measurements by m/s in the LA.The results obtained in our study could be a reference point for evaluating stiffness of the common fibular nerve in research involving different pathologies.

摘要

本研究旨在探讨健康成年受试者腓总神经的声触诊组织量化弹性成像特征。这是一项观察性的横断面研究。使用剪切波弹性成像评估腓总神经。测量横截面积和杨氏模量(kPa 和 m/s)。该研究纳入了 41 名健康成年受试者的 82 条腓总神经。腓骨头处腓总神经的平均横截面积为 8.7mm²。两种方法测量的短轴和长轴杨氏模量之间均呈正相关。短轴的腓总神经平均杨氏模量为 22.5kPa,长轴为 35.4kPa。两种方法测量的 kPa 时,身高与杨氏模量均呈正相关。m/s 时,短轴的腓总神经平均杨氏模量为 2.6m/s,长轴为 3.4m/s。身高与 m/s 时杨氏模量的两个轴均呈正相关。体重与长轴的 m/s 时杨氏模量呈正相关。本研究的结果可为不同病变研究中腓总神经杨氏模量的评估提供参考。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3194/10684218/4128064f4d86/medi-101-e29052-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验