Jin Xinrui, Zhao Yuanqing, Gu Xiujuan, Zhong Min, Kong Xin, Li Guangrong, Tian Gang, Liu Jinbo
Department of Laboratory Medicine, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan 646000, China.
J Anal Methods Chem. 2022 Mar 29;2022:3998338. doi: 10.1155/2022/3998338. eCollection 2022.
Simple, rapid, and accurate detection of myoinositol (MI) concentration in blood is crucial in diagnosing polycystic ovary syndrome, neurological disorders, and cancer. A novel electrochemical detection (IED) method was established to quantify MI in human serum using a disposable unmodified screen-printed carbon electrode (SPCE) for the first time. MI was detected indirectly by the reaction product of myoinositol dehydrogenase (IDH) and cofactor -nicotinamide adenine dinucleotide (NAD). Good linear calibration curves were obtained at the concentration range from 5.0 M to 500.0 M ( = 0.9981) with the lower limits of detection (LOD) and quantification (LOQ) of 1.0 M and 2.5 M, respectively. Recoveries were calculated at three spiked concentrations, and the values were between 90.3 and 106%, with relative standard deviation values of 3.2-6.2% for intraday precision and 7.1-9.0% for interday precision. The SPCE-electrochemical biosensor is simple, accurate, and without modification, showing great potential for point-of-care testing (POCT) of serum MI in clinical samples.
简单、快速且准确地检测血液中的肌醇(MI)浓度对于诊断多囊卵巢综合征、神经系统疾病和癌症至关重要。首次建立了一种新型电化学检测(IED)方法,使用一次性未修饰的丝网印刷碳电极(SPCE)对人血清中的MI进行定量。通过肌醇脱氢酶(IDH)与辅因子烟酰胺腺嘌呤二核苷酸(NAD)的反应产物间接检测MI。在5.0 μM至500.0 μM的浓度范围内获得了良好的线性校准曲线(r = 0.9981),检测限(LOD)和定量限(LOQ)分别为1.0 μM和2.5 μM。在三个加标浓度下计算回收率,回收率在90.3%至106%之间,日内精密度的相对标准偏差值为3.2 - 6.2%,日间精密度的相对标准偏差值为7.1 - 9.0%。该SPCE - 电化学生物传感器简单、准确且无需修饰,在临床样本血清MI的即时检测(POCT)中显示出巨大潜力。