Suppr超能文献

一种基于磁分离的用于同时检测噻虫嗪和葡聚糖的多色上转换荧光免疫分析法的开发。

Development of a multicolor upconversion fluorescence immunoassay for the simultaneous detection of thiamethoxam and dextran by magnetic separation.

作者信息

Li Chuanyong, Sun Wanlin, Huang Lianrun, Sun Nana, Hua Xiude, Wang Minghua, Liu Fengquan

机构信息

College of Plant Protection, Nanjing Agricultural University Nanjing 210095 China

Institute of Plant Protection, Jiangsu Academy of Agricultural Science Nanjing 210014 China.

出版信息

RSC Adv. 2020 Dec 23;11(1):517-524. doi: 10.1039/d0ra07954e. eCollection 2020 Dec 21.

Abstract

The contents of both pesticide residues and dextran are important parameters for evaluating the quality of sugarcane. In this study, a multicolor upconversion fluorescence immunoassay for the simultaneous detection of thiamethoxam and dextran was established on the basis of magnetic separation. Antigens of thiamethoxam and dextran were coupled to magnetic nanoparticles as the separation elements. Monoclonal antibodies of thiamethoxam (6C7D12) and dextran (3C6F7) were conjugated with the upconversion nanoparticles of NaYF:Yb,Er with an emission wavelength at 544 nm and NaYF:Yb,Tm with an emission wavelength at 477 nm to prepare the signaling elements, respectively. Due to the difference in the emission wavelength, the signaling elements bound on the separation elements could be detected simultaneously after separation by an external magnetic field. After optimization, the half-maximal inhibitory concentration (IC) values of the immunoassay for thiamethoxam and dextran were 0.46 and 49.33 ng mL, respectively. The assay showed no cross-reactivity with the analogs of thiamethoxam and dextran except for clothianidin (8.7%). The average recoveries of thiamethoxam and dextran in sugarcane juice were 82.9-93.3% and 87.5-97.2%, respectively. The results indicated that the immunoassay could meet the requirements for the simultaneous quantitative detection of thiamethoxam and dextran.

摘要

农药残留和葡聚糖的含量都是评估甘蔗品质的重要参数。在本研究中,基于磁分离技术建立了一种用于同时检测噻虫嗪和葡聚糖的多色上转换荧光免疫分析方法。将噻虫嗪和葡聚糖的抗原偶联到磁性纳米颗粒上作为分离元件。将噻虫嗪单克隆抗体(6C7D12)和葡聚糖单克隆抗体(3C6F7)分别与发射波长为544 nm的NaYF:Yb,Er上转换纳米颗粒和发射波长为477 nm的NaYF:Yb,Tm上转换纳米颗粒偶联,制备信号元件。由于发射波长的差异,通过外部磁场分离后,可以同时检测结合在分离元件上的信号元件。经过优化,该免疫分析方法对噻虫嗪和葡聚糖的半数抑制浓度(IC)值分别为0.46和49.33 ng/mL。除了噻虫胺(交叉反应率为8.7%)外,该分析方法对噻虫嗪和葡聚糖的类似物没有交叉反应。甘蔗汁中噻虫嗪和葡聚糖的平均回收率分别为82.9 - 93.3%和87.5 - 97.2%。结果表明,该免疫分析方法能够满足同时定量检测噻虫嗪和葡聚糖的要求。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ac0e/8690861/a0e5d2b3944c/d0ra07954e-f1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验