飞秒激光小切口基质透镜切除术、波前优化准分子原位角膜磨镶术和角膜地形图引导的准分子原位角膜磨镶术矫正近视及近视散光后的角膜光学质量比较

Comparison of Corneal Optical Quality After SMILE, Wavefront-Optimized LASIK and Topography-Guided LASIK for Myopia and Myopic Astigmatism.

作者信息

Zhang Yu, Sun Xiaoxiao, Chen Yueguo

机构信息

Department of Ophthalmology, Peking University Third Hospital, Beijing, China.

Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China.

出版信息

Front Med (Lausanne). 2022 Apr 5;9:870330. doi: 10.3389/fmed.2022.870330. eCollection 2022.

Abstract

PURPOSE

To compare visual outcomes and corneal optical quality after small incision lenticule extraction (SMILE), wavefront-optimized (WFO) FS-LASIK, and topography-guided customized ablation treatment (TCAT) FS-LASIK for myopia.

METHODS

This prospective case-series study included 283 eyes of 283 myopic patients who underwent SMILE or FS-LASIK. There were 102, 100, and 81 eyes in the SMILE group, WFO group and TCAT group, respectively. The tomography system (Sirius) was used to measure corneal aberrations and optical quality.

RESULTS

At postoperative 1 and 6 months, there were no significant differences in uncorrected distance visual acuity and corrected distance visual acuity among the three groups ( > 0.05). Postoperative manifest refractive spherical equivalent was similar among the groups ( > 0.05). There was statistically significant difference in cylinder at 1 month among the three groups, with the highest mean value in TCAT group ( < 0.05). The corneal optical path difference, root mean square of corneal astigmatism and strehl ratio were the most superior in the TCAT group at postoperative 1 and 6 months ( < 0.05).

CONCLUSION

SMILE, WFO FS-LASIK, and TCAT FS-LASIK provided similar visual results. The corneal visual quality after TCAT FS-LASIK was the best.

摘要

目的

比较小切口基质透镜切除术(SMILE)、波前优化(WFO)飞秒激光原位角膜磨镶术(FS-LASIK)和地形引导个性化消融治疗(TCAT)FS-LASIK矫正近视后的视觉效果和角膜光学质量。

方法

这项前瞻性病例系列研究纳入了283例接受SMILE或FS-LASIK手术的近视患者的283只眼。SMILE组、WFO组和TCAT组分别有102只、100只和81只眼。使用断层扫描系统(Sirius)测量角膜像差和光学质量。

结果

术后1个月和6个月时,三组间的裸眼远视力和矫正远视力无显著差异(>0.05)。各组术后明显屈光球镜等效度相似(>0.05)。三组间术后1个月时的柱镜有统计学显著差异,TCAT组的平均值最高(<0.05)。术后1个月和6个月时,TCAT组的角膜光程差、角膜散光均方根和斯特列尔比最优异(<0.05)。

结论

SMILE、WFO FS-LASIK和TCAT FS-LASIK提供了相似的视觉效果。TCAT FS-LASIK术后的角膜视觉质量最佳。