线性与凸阵探头在超声造影(CEUS)评估可疑乳腺病变增强特征中的比较

Comparison of Linear and Convex-Array Transducers in Assessing the Enhancement Characteristics of Suspicious Breast Lesions at Contrast-Enhanced Ultrasound (CEUS).

作者信息

Boca Bene Ioana, Ciurea Anca Ileana, Ciortea Cristiana Augusta, Vesa Ștefan Cristian, Dudea Sorin Marian

机构信息

Department of Radiology, "Iuliu Hatieganu" University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.

Department of Radiology, Emergency County Hospital, 400006 Cluj-Napoca, Romania.

出版信息

Diagnostics (Basel). 2022 Mar 24;12(4):798. doi: 10.3390/diagnostics12040798.

Abstract

The purpose of this study was to determine the observer agreement in assessing the enhancement pattern of suspicious breast lesions with contrast-enhanced ultrasound (CEUS) using high and low frequency transducers. Methods: This prospective study included 70 patients with suspicious breast lesions detected at mammography and/or ultrasound and classified according to the American College of Radiology (ACR) Breast Imaging-Reporting and Data System (BI-RADS) in 4A, 4B, 4C, or 5, who underwent CEUS examinations between October 2020 and August 2021. Results: Participants’ ages ranged from 28 to 83 years (48.5 + 6.36, mean age + SD). We obtained a substantial agreement for the first reader (kappa = 0.614, p < 0.001) and a perfect agreement for the second and third reader (kappa = 1, p < 0.001) between the two transducers for the uptake pattern. A moderate agreement for the second and third reader (kappa = 0.517 and 0.538, respectively, p < 0.001) and only a fair agreement (kappa = 0.320, p < 0.001) in the case of the first reader for the perilesional enhancement was observed. We obtained an excellent inter-observer agreement (Cronbach’s Alpha coefficient = 0.960, p < 0.001) for the degree of enhancement, a good inter-observer agreement for the uptake pattern and perilesional enhancement (Cronbach’s Alpha coefficient = 0.831 and 0.853, respectively, p < 0.001), and a good and acceptable inter-observer agreement for internal homogeneity, perfusion defects and margins of the lesions (Cronbach’s Alpha coefficient = 0.703, 0.703 and 0.792, respectively, p < 0.001) concerning the evaluation of breast lesions with the linear-array transducer. Conclusions: The evaluation of suspicious breast lesions by three experts with high-frequency linear-array transducer and low-frequency convex-array transducer was comparable in terms of uptake pattern and perilesional enhancement. The agreement regarding the evaluation of the degree of enhancement, the internal homogeneity, and the perfusion defects varied between fair and substantial. For all CEUS characteristics, the inter-observer agreement was superior for linear-array transducer, which leads to more a homogeneous and reproducible interpretation.

摘要

本研究的目的是确定使用高频和低频换能器通过超声造影(CEUS)评估可疑乳腺病变增强模式时的观察者一致性。方法:这项前瞻性研究纳入了70例在乳腺X线摄影和/或超声检查中发现可疑乳腺病变的患者,这些病变根据美国放射学会(ACR)乳腺影像报告和数据系统(BI-RADS)分类为4A、4B、4C或5类,于2020年10月至2021年8月期间接受了CEUS检查。结果:参与者年龄在28至83岁之间(平均年龄48.5 + 6.36,均值±标准差)。对于摄取模式,两位换能器之间,第一位读者达成了高度一致性(kappa = 0.614,p < 0.001),第二位和第三位读者达成了完全一致性(kappa = 1,p < 0.001)。对于病变周围增强,观察到第二位和第三位读者达成了中度一致性(kappa分别为0.517和0.538,p < 0.001),而第一位读者仅达成了一般一致性(kappa = 0.320,p < 0.001)。对于增强程度,我们获得了极好的观察者间一致性(Cronbach's Alpha系数 = 0.960,p < 0.001);对于摄取模式和病变周围增强,获得了良好的观察者间一致性(Cronbach's Alpha系数分别为0.831和0.853,p < 0.001);对于病变的内部均匀性、灌注缺损和边缘,在使用线阵换能器评估乳腺病变方面,获得了良好且可接受的观察者间一致性(Cronbach's Alpha系数分别为0.703、0.703和0.792,p < 0.001)。结论:三位专家使用高频线阵换能器和低频凸阵换能器对可疑乳腺病变进行评估时,在摄取模式和病变周围增强方面具有可比性。在增强程度、内部均匀性和灌注缺损评估方面的一致性介于一般和高度之间。对于所有CEUS特征,线阵换能器的观察者间一致性更佳,这使得解读更加均匀且可重复。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e338/9025659/e1fa274ea252/diagnostics-12-00798-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验