急性脑静脉窦血栓形成中脑非增强计算机断层扫描和D-二聚体水平的诊断效用:一项定量研究。

The diagnostic utility of unenhanced computed tomography of the brain and D-dimer levels in acute cerebral venous sinus thrombosis: A quantitative study.

作者信息

Alharbi Omar Abdullah, Alahmadi Khalid Omar

机构信息

Department of Radiology, King Faisal Specialist Hospital & Research Centre, Riyadh, Saudi Arabia.

出版信息

J Clin Imaging Sci. 2022 Apr 16;12:15. doi: 10.25259/JCIS_76_2021. eCollection 2022.

Abstract

OBJECTIVES

(1) To calculate the sensitivity and specificity of the Hounsfield Unit (HU), the HU to hematocrit (H:H) ratio, and the D-dimer level in the diagnosis of acute CVST. (2) To assess the D-dimer level's linear relationship with the HU and the H:H ratio.

MATERIALS AND METHODS

A single-center retrospective case-control study was conducted from 2005 to 2020. The inclusion criteria for the thrombosed and control groups were specified. A region of interest (ROI) was plotted on the respective sinuses to calculate the HU. The H:H ratio was calculated by dividing the HU value by the hematocrit value. The receiver operating characteristic curve was used to calculate the sensitivity and specificity of the HU and the H:H ratio at different cutoff values. The Pearson correlation was used to assess the linear relationship between the D-dimer level and the HU and H:H ratio.

RESULTS

There were 19 patients in the thrombosed group and 28 patients in the control group. There were significant differences in the mean HU (71 ± 6.3 vs. 45 ± 4.8, < 0.001) and the mean H:H ratio (2.11 ± 0.38 vs. 1.46 ± 0.63, < 0.001). An optimal HU value of 56 yielded 100% sensitivity and specificity. An H:H value of 1.48 yielded a sensitivity of 100% and a specificity of 65%, an H:H ratio of 1.77 demonstrated a sensitivity of 85% and a specificity of 90%, and an H:H ratio of 1.88 yielded a sensitivity of 79% and a specificity of 93%. D-dimer levels had a 95% and 71% sensitivity and specificity, respectively. There was a significant moderately positive linear correlation between the D-dimer level and the HU (r = 0.52, < 0.001) and the H:H ratio (r = 0.61, < 0.001).

CONCLUSION

Unenhanced CT of the brain can be a valuable objective diagnostic tool for acute CVST diagnosis. Hounsfield blood density and its normalized ratio with hematocrit are positively correlated with D-dimer levels, which may indicate active blood coagulation in a cerebral venous sinus.

摘要

目的

(1)计算霍夫曼单位(HU)、HU与血细胞比容之比(H:H)以及D-二聚体水平在急性脑静脉窦血栓形成(CVST)诊断中的敏感性和特异性。(2)评估D-二聚体水平与HU和H:H比值的线性关系。

材料与方法

进行了一项2005年至2020年的单中心回顾性病例对照研究。明确了血栓形成组和对照组的纳入标准。在各自的静脉窦上绘制感兴趣区域(ROI)以计算HU。H:H比值通过将HU值除以血细胞比容值来计算。采用受试者工作特征曲线计算不同临界值下HU和H:H比值的敏感性和特异性。使用Pearson相关性评估D-二聚体水平与HU和H:H比值之间的线性关系。

结果

血栓形成组有19例患者,对照组有28例患者。平均HU(71±6.3对45±4.8,<0.001)和平均H:H比值(2.11±0.38对1.46±0.63,<0.001)存在显著差异。最佳HU值为56时,敏感性和特异性均为100%。H:H值为1.48时,敏感性为100%,特异性为65%;H:H比值为1.77时,敏感性为85%,特异性为90%;H:H比值为1.88时,敏感性为79%,特异性为93%。D-二聚体水平的敏感性和特异性分别为95%和71%。D-二聚体水平与HU(r = 0.52,<0.001)和H:H比值(r = 0.61,<0.001)之间存在显著的中度正线性相关性。

结论

脑部平扫CT可作为急性CVST诊断的有价值的客观诊断工具。霍夫曼血液密度及其与血细胞比容的标准化比值与D-二聚体水平呈正相关,这可能表明脑静脉窦存在活跃的血液凝固。