Alsafi Ali, Lakhani Amish, Carlton Jones Lalani, Lobotesis Kyriakos
Department of Neuroradiology, Charing Cross Hospital, Imperial College Healthcare NHS, London W6 8RF, UK.
Radiol Res Pract. 2015;2015:581437. doi: 10.1155/2015/581437. Epub 2015 May 11.
Purpose. Retrospectively evaluate the density of cerebral venous sinuses in nonenhanced head CTs (NCTs) and correlate these with the presence or absence of a cerebral venous sinus thrombus (CVST). Materials and Methods. Institutional review board approval was obtained and informed consent waived prior to commencing this retrospective study. Over a two-year period, all CT venograms (CTVs) performed at our institution were retrieved and the preceding/subsequent NCTs evaluated. Hounsfield Units (HUs) of thrombus when present as well as that of normal superior sagittal and sigmoid sinuses were measured. HU of thrombus was compared to that of normal vessels with and without standardisation to the average HU of the internal carotid arteries. Results. 299 CTVs were retrieved, 26 with a thrombus. Both raw and standardised HU measurements were significantly higher in CVST (p < 0.0001) compared to normal vessels. Both raw and standardised HUs are good predictors of CVST. A HU of ≥67 and a standardised measurement of ≥1.5 are associated with high probability of CVST on NCT. Conclusion. Cerebral venous sinus HU measurements may help improve sensitivity and specificity of NCT for venous sinus thrombosis and avoid potentially unnecessary follow-up examinations.
目的。回顾性评估非增强头部CT(NCT)中脑静脉窦的密度,并将其与脑静脉窦血栓形成(CVST)的有无相关联。材料与方法。在开始这项回顾性研究之前,获得了机构审查委员会的批准并豁免了知情同意。在两年的时间里,检索了我们机构进行的所有CT静脉造影(CTV),并对之前/之后的NCT进行了评估。测量了存在血栓时血栓的亨氏单位(HU)以及正常上矢状窦和乙状窦的HU。将血栓的HU与正常血管的HU进行比较,并且在标准化到颈内动脉的平均HU的情况下进行比较。结果。检索到299例CTV,其中26例有血栓形成。与正常血管相比,CVST中原始和标准化的HU测量值均显著更高(p < 0.0001)。原始和标准化的HU都是CVST的良好预测指标。在NCT上,HU≥67和标准化测量值≥1.5与CVST的高概率相关。结论。脑静脉窦HU测量可能有助于提高NCT对静脉窦血栓形成的敏感性和特异性,并避免潜在的不必要的后续检查。