Song Yingpan, He Lina, Chen Kun, Wang Minghua, Yang Longyu, He Linghao, Guo Chuanpan, Jia Qiaojuan, Zhang Zhihong
Henan Provincial Key Laboratory of Surface and Interface Science, Zhengzhou University of Light Industry No. 136, Science Avenue Zhengzhou 450001 P. R. China
RSC Adv. 2020 Jul 29;10(47):28355-28364. doi: 10.1039/d0ra01439g. eCollection 2020 Jul 27.
A new bimetallic CuCo Prussian blue analogue (CuCo PBA) loaded with carbon dots (CDs) was prepared (represented by CD@CuCoPBA) and developed as a scaffold for anchoring the epidermal growth factor receptor (EGFR) aptamer to detect EGFR and living EGFR-overexpressed cancer cells. The basic characterizations revealed CuCo PBA exhibited nanocube shape and still remained its nanostructure and physical/chemical properties after coupling with large amounts of CDs. As compared with the pristine CuCo PBA, the CD@CuCoPBA displayed good electrochemical activity, strong binding interaction toward aptamer, and high stability of aptamer-EGFR G-quadruplex in aqueous solution. As such, the results of electrochemical impedance spectroscopy measurements indicated that the CD@CuCoPBA-based aptasensor displayed an ultra-low detection limit toward EGFR (0.42 fg mL) and living EGFR-overexpressed MCF-7 cancer cells (80 cell per mL), as well as high selectivity, good reproducibility, high stability, repeatability, and acceptable applicability. Consequently, the constructed CD@CuCoPBA-based aptasensor can be extended to be a promising universal method for early diagnosis of cancers.
制备了一种负载碳点(CDs)的新型双金属铜钴普鲁士蓝类似物(CuCo PBA,以CD@CuCoPBA表示),并将其开发为一种支架,用于锚定表皮生长因子受体(EGFR)适配体,以检测EGFR和活的EGFR过表达癌细胞。基本表征表明,CuCo PBA呈现纳米立方体形状,与大量CDs偶联后仍保留其纳米结构和物理/化学性质。与原始CuCo PBA相比,CD@CuCoPBA表现出良好的电化学活性、对适配体的强结合相互作用以及适配体-EGFR G-四链体在水溶液中的高稳定性。因此,电化学阻抗谱测量结果表明,基于CD@CuCoPBA的适配体传感器对EGFR(0.42 fg/mL)和活的EGFR过表达MCF-7癌细胞(每毫升80个细胞)显示出超低检测限,以及高选择性、良好的重现性、高稳定性、可重复性和可接受的适用性。因此,构建的基于CD@CuCoPBA的适配体传感器可扩展为一种有前景的癌症早期诊断通用方法。