A new bimetallic CuCo Prussian blue analogue (CuCo PBA) loaded with carbon dots (CDs) was prepared (represented by CD@CuCoPBA) and developed as a scaffold for anchoring the epidermal growth factor receptor (EGFR) aptamer to detect EGFR and living EGFR-overexpressed cancer cells. The basic characterizations revealed CuCo PBA exhibited nanocube shape and still remained its nanostructure and physical/chemical properties after coupling with large amounts of CDs. As compared with the pristine CuCo PBA, the CD@CuCoPBA displayed good electrochemical activity, strong binding interaction toward aptamer, and high stability of aptamer-EGFR G-quadruplex in aqueous solution. As such, the results of electrochemical impedance spectroscopy measurements indicated that the CD@CuCoPBA-based aptasensor displayed an ultra-low detection limit toward EGFR (0.42 fg mL) and living EGFR-overexpressed MCF-7 cancer cells (80 cell per mL), as well as high selectivity, good reproducibility, high stability, repeatability, and acceptable applicability. Consequently, the constructed CD@CuCoPBA-based aptasensor can be extended to be a promising universal method for early diagnosis of cancers.

摘要

制备了一种负载碳点(CDs)的新型双金属铜钴普鲁士蓝类似物(CuCo PBA,以CD@CuCoPBA表示),并将其开发为一种支架,用于锚定表皮生长因子受体(EGFR)适配体,以检测EGFR和活的EGFR过表达癌细胞。基本表征表明,CuCo PBA呈现纳米立方体形状,与大量CDs偶联后仍保留其纳米结构和物理/化学性质。与原始CuCo PBA相比,CD@CuCoPBA表现出良好的电化学活性、对适配体的强结合相互作用以及适配体-EGFR G-四链体在水溶液中的高稳定性。因此,电化学阻抗谱测量结果表明,基于CD@CuCoPBA的适配体传感器对EGFR(0.42 fg/mL)和活的EGFR过表达MCF-7癌细胞(每毫升80个细胞)显示出超低检测限,以及高选择性、良好的重现性、高稳定性、可重复性和可接受的适用性。因此,构建的基于CD@CuCoPBA的适配体传感器可扩展为一种有前景的癌症早期诊断通用方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cbb1/9055645/25fe36dd4537/d0ra01439g-f2.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验