Whitehead J
Biometrics. 1986 Sep;42(3):461-71.
Suppose that a clinical trial has been carried out using a sequential design. Any analysis that neglects the monitoring of the trial is potentially biased, and this holds for analyses of responses not directly used to determine whether the study should be stopped. Although valid methods exist to deal with the responses actually used in the sequential design, little has been written about secondary analyses of further responses. In this paper, two approaches to secondary analyses are explored. One is a conditional approach that avoids the problems of bias, the other an unconditional approach that allows for the sequential nature of the trial. The two methods are illustrated by application to three examples, each concerning a different type of response variable.
假设一项临床试验采用序贯设计进行。任何忽略试验监测的分析都可能存在偏差,对于那些并非直接用于决定研究是否应停止的反应分析而言亦是如此。尽管存在有效的方法来处理序贯设计中实际使用的反应,但关于对其他反应进行二次分析的论述却很少。本文探讨了两种二次分析方法。一种是避免偏差问题的条件性方法,另一种是考虑试验序贯性质的非条件性方法。通过应用于三个示例对这两种方法进行了说明,每个示例涉及不同类型的反应变量。