To assess the clinical and radiological outcomes after ACDF with 3D printed cellular titanium cages filled with bone marrow and to compare the clinical and radiological results with the current scientific literature.
ACDF was performed monosegmentally under standardized conditions. X-rays were analyzed to determine the range of motion, fusion rates, and subsidence preoperatively and 3 and 12 months postoperatively. Clinical outcome measurements included neck disability index (NDI), visual analogue scale (VAS) for brachialgia and cervicalgia, and patient satisfaction.
18 patients were included in the study. The mean RoM decreased from 7.7° ± 2.6 preoperatively to 1.7° ± 1.1° after 3 months and 1.8° ± 1.2° 12 months after surgery. The fusion rates were at 94.4% after 3 and 12 months. The mean subsidence was 0.9 mm ± 0.5 mm 3 months postoperatively and 1.1 mm ± 0.5 mm 12 months after surgery. The mean NDI improved significantly from preoperatively to 12 months postoperatively (34.6 ± 6.2 and 3.4 ± 4.1, respectively). The VAS-neck also showed a large improvement from 5.8 ± 2.2 before and 1.3 ± 1.4 12 months after surgery, as did the VAS-arm (6.4 ± 1.5 and 0.9 ± 1.6, respectively). Patient satisfaction was high throughout the follow-up period.
ACDF with a 3D printed titanium cage resulted in fast fusion without pathological subsidence. In comparison to other cage materials such as PEEK, the 3D printed titanium cage was noninferior in regard to its fusion rate and clinical results.
评估使用填充骨髓的 3D 打印多孔钛笼行颈椎前路椎体间融合术(ACDF)的临床和影像学结果,并与当前科学文献进行比较。
在标准化条件下进行单节段 ACDF。分析 X 射线以确定术前、术后 3 个月和 12 个月的活动范围、融合率和沉降。临床结果测量包括颈部残疾指数(NDI)、颈臂痛视觉模拟评分(VAS)和患者满意度。
研究纳入 18 例患者。术后 3 个月和 12 个月时,平均 RoM 分别从术前的 7.7°±2.6°降至 1.7°±1.1°和 1.8°±1.2°。术后 3 个月和 12 个月的融合率分别为 94.4%。术后 3 个月和 12 个月时,平均沉降分别为 0.9mm±0.5mm 和 1.1mm±0.5mm。术后 12 个月时,NDI 从术前显著改善(分别为 34.6±6.2 和 3.4±4.1)。VAS-颈也从术前的 5.8±2.2 改善到术后 12 个月的 1.3±1.4(分别),VAS-臂也从术前的 6.4±1.5 改善到术后 12 个月的 0.9±1.6(分别)。整个随访期间,患者满意度均较高。
使用 3D 打印钛笼行 ACDF 可快速融合且无病理性沉降。与 PEEK 等其他笼材料相比,3D 打印钛笼在融合率和临床结果方面不劣于后者。