A peri-implant fracture near the volar plate of the distal radius represents a rarity and can be associated with a mechanical failure of the devices. A literature review was conducted including all fractures that occurred around a volar wrist plate, which could be associated with an ulna fracture. All articles published until December 2021 were considered according to the guidelines presented in the PRISMA Statement. The search was conducted with the PubMed electronic database, Cochrane Database of Systematic Reviews, Medline, Embase, and Google Scholar. Only nine cases of these fractures were reported in the literature. The causes could be due to delayed union/non-union of the old fracture after low energy traumas, high energy trauma in patients with poor bone quality, or hardware mechanical failure. Furthermore, the literature review of peri-implant radius fracture shows different level of radius fracture and types of implant failure. In accordance with these different cases, a new classification of peri-implant fracture of the distal radius is proposed.
桡骨远端掌侧板附近的种植体周围骨折较为罕见,可能与器械的机械故障有关。我们进行了一项文献综述,纳入了所有发生在掌侧腕板周围且可能与尺骨骨折相关的骨折病例。根据PRISMA声明中提出的指南,检索了截至2021年12月发表的所有文章。检索使用了PubMed电子数据库、Cochrane系统评价数据库、Medline、Embase和谷歌学术。文献中仅报道了9例此类骨折。其原因可能是低能量创伤后陈旧性骨折的延迟愈合/不愈合、骨质量差的患者遭受高能量创伤或硬件机械故障。此外,关于种植体周围桡骨骨折的文献综述显示了不同程度的桡骨骨折和种植体失败类型。根据这些不同病例,提出了一种新的桡骨远端种植体周围骨折分类方法。