Suppr超能文献

两种不同光固化机及固化时间对大块充填修复材料的影响

The Effect of Two Different Light-Curing Units and Curing Times on Bulk-Fill Restorative Materials.

作者信息

Bayrak Gokcen Deniz, Yaman-Dosdogru Elif, Selvi-Kuvvetli Senem

机构信息

Department of Pediatric Dentistry, Faculty of Dentistry, University of Yeditepe, Bagdat Cd. No. 238, Istanbul 34728, Turkey.

出版信息

Polymers (Basel). 2022 May 5;14(9):1885. doi: 10.3390/polym14091885.

Abstract

This study aimed to evaluate the effect of two different light-curing units and curing times on the surface microhardness (SMH), compressive strength (CS), and volumetric shrinkage (VS) of four restorative materials (Filtek Z250, Filtek Bulk Fill Posterior, Beautifil Bulk Restorative, ACTIVA BioACTIVE). For all tests, each material was divided into two groups depending on the curing unit (Woodpecker LED-E and CarboLED), and each curing unit group was further divided into two subgroups according to curing time (10 s and 20 s). SMH was evaluated using a Vickers hardness tester, CS was tested using a universal testing machine, and VS was measured using video imaging. In all the restorative materials cured with Woodpecker LED-E, the 20 s subgroup demonstrated significantly higher SMH values than the 10 s subgroup. In both light-curing time subgroups, the CarboLED group showed significantly higher CS values than the Woodpecker LED-E group for all restorative materials except Filtek Bulk Fill Posterior cured for 20 s. ACTIVA BioACTIVE showed significantly greater volumetric change than the other restorative materials. A higher curing light intensity and longer curing time had a positive effect on the SMH and CS of the restorative materials tested in this study. On the other hand, curing unit and time did not show a significant effect on the VS values of restorative materials.

摘要

本研究旨在评估两种不同的光固化机及固化时间对四种修复材料(Filtek Z250、Filtek Bulk Fill Posterior、Beautifil Bulk Restorative、ACTIVA BioACTIVE)的表面显微硬度(SMH)、抗压强度(CS)和体积收缩率(VS)的影响。对于所有测试,每种材料根据固化机(啄木鸟LED-E和CarboLED)分为两组,每个固化机组又根据固化时间(10秒和20秒)进一步分为两个亚组。使用维氏硬度计评估表面显微硬度,使用万能试验机测试抗压强度,使用视频成像测量体积收缩率。在用啄木鸟LED-E固化的所有修复材料中,20秒亚组的表面显微硬度值显著高于10秒亚组。在两个光固化时间亚组中,除Filtek Bulk Fill Posterior固化20秒外,对于所有修复材料,CarboLED组的抗压强度值均显著高于啄木鸟LED-E组。ACTIVA BioACTIVE的体积变化显著大于其他修复材料。更高的固化光强度和更长的固化时间对本研究中测试的修复材料的表面显微硬度和抗压强度有积极影响。另一方面,固化机和固化时间对修复材料的体积收缩率值没有显著影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d997/9104037/da58dd7c4c6b/polymers-14-01885-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验