Background: This investigation aimed to radiographically assess the variations of graft dimension following maxillary sinus augmentation by the lateral approach. Methods: Eighteen patients (seven males), with a mean age at surgery of 66.5 ± 9.8 (range 52−82) years, were unilaterally treated. Thirty-five dental implants were positioned in the posterior maxilla simultaneously to grafting with heterologous biomaterials. Intraoral radiographs taken at the time of surgery, after six months, and at the longest follow-up (up to nine years after implant placement) were analyzed. The following distances were measured: mesio-distal width of the graft, vertical distance from implant apex to most coronal level of the graft, distance from the mesial aspect of the (mesial) implant to the mesial graft extension; distance from the distal aspect of the (distal) implant to the distal graft extension, and graft height along the implant axis. The dimensional changes with respect to baseline, after six months and at the longest follow-up were calculated. Results: The patient-based mean follow-up was 38.3 ± 30.1 months (range 12−108 months). The mean residual bone height at the mesial and distal aspect of the implants was 3.19 ± 2.05 mm and 2.65 ± 1.60 mm, respectively (p = 0.38). The mean graft width at baseline was 27.95 ± 5.23 mm, and the mean graft width reduction was 10.2 ± 12.7% (2.98 ± 3.62 mm) and 11.3 ± 14.4% (3.36 ± 4.08 mm) at six months and at the latest follow-up. The change was significant at six months (p = 0.005), but did not show significant further variation (p = 0.11). On the mesial and distal aspect, the mean graft extension decreased by 1.56 ± 2.67 mm and 0.84 ± 2.71 mm at the latest follow-up. No significant difference between mesial and distal changes was found (p = 0.24), suggesting that the biomaterial is resorbed homogeneously on both sides. The mean graft height was 11.92 ± 2.53 mm at baseline and decreased by 9.3 ± 9.05% (1.11 ± 1.09 mm) at six months (p < 0.001). Non-significant further changes were found at the latest follow-up (p = 0.10). Conclusions: after early remodeling, heterologous bone substitutes showed a good dimensional stability in the mid-term for maxillary sinus augmentation.
本研究旨在通过影像学评估外侧入路上颌窦提升术后植骨块尺寸的变化。方法:18例患者(7例男性)接受单侧治疗,手术时的平均年龄为66.5±9.8岁(范围52 - 82岁)。35颗牙种植体在植入异体生物材料的同时被植入上颌后部。分析手术时、术后6个月以及最长随访期(种植体植入后长达9年)拍摄的口腔内X光片。测量以下距离:植骨块的近远中宽度、种植体根尖至植骨块最冠方水平的垂直距离、(近中)种植体近中面至植骨块近中延伸部的距离、(远中)种植体远中面至植骨块远中延伸部的距离以及沿种植体长轴的植骨块高度。计算相对于基线、术后6个月及最长随访期的尺寸变化。结果:以患者为基础的平均随访时间为38.3±30.1个月(范围12 - 108个月)。种植体近中及远中面的平均剩余骨高度分别为3.19±2.05mm和2.65±1.60mm(p = 0.38)。基线时植骨块的平均宽度为27.95±5.23mm,术后6个月及最新随访时植骨块平均宽度减少分别为10.2±12.7%(2.98±3.62mm)和11.3±14.4%(3.36±4.08mm)。6个月时变化显著(p = 0.005),但未显示出进一步的显著变化(p = 0.11)。在近中及远中面,最新随访时植骨块的平均延伸分别减少了1.56±2.67mm和0.84±2.71mm。近中与远中变化之间未发现显著差异(p = 0.24),表明生物材料在两侧均匀吸收。基线时植骨块的平均高度为11.92±2.53mm,术后6个月减少了9.3±9.05%(1.11±1.09mm)(p < 0.001)。最新随访时未发现显著的进一步变化(p = 0.10)。结论:早期重塑后,异体骨替代物在上颌窦提升中期显示出良好的尺寸稳定性。