5S 研究:镇静下使用脉冲场消融的安全、简便的单次肺静脉隔离术。

5S Study: Safe and Simple Single Shot Pulmonary Vein Isolation With Pulsed Field Ablation Using Sedation.

机构信息

Cardioangiologisches Centrum Bethanien (B.S., S.B., S.T., S.C., F.B., L.U., F.P., M.E., K.R.J.C.), Frankfurt, Germany.

Universitätsklinikum Frankfurt, Medizinische Klinik 3- Klinik für Kardiologie (B.S.), Frankfurt, Germany.

出版信息

Circ Arrhythm Electrophysiol. 2022 Jun;15(6):e010817. doi: 10.1161/CIRCEP.121.010817. Epub 2022 May 26.

Abstract

BACKGROUND

Pulsed field ablation represents an energy source specific for ablation of cardiac arrhythmias including atrial fibrillation. The aim of the study was to describe the adoption and the process of streamlining procedures with a new ablation technology.

METHODS

All-comer atrial fibrillation patients (n=191; mean age 69±12 years) underwent catheter ablation with a pulsed field ablation ablation device exclusively using analog-sedation. In the validation phase (n=25), device electrogram quality was compared with a circular mapping catheter to assess pulmonary vein isolation and esophageal temperature monitoring was used. In the streamline phase (n=166), a single-catheter approach was implemented. Postprocedural cerebral magnetic resonance imaging was performed in 53 patients. In 52 patients, esophageal endoscopy was performed at day 1 after the procedure. Follow-up was performed using 72 hours Holter ECGs.

RESULTS

On a pulmonary vein basis, pulmonary vein isolation rate was 100% including a single shot isolation rate of 99.5%. The electrogram information of the pulsed field ablation catheter and the circular mapping catheter were 100% congruent. Neither esophageal temperature rises nor esophageal thermal injury were observed. Two minor strokes occurred, presumable due to air embolism during catheter exchanges through the large bore sheath (13.8 F ID). In the streamline phase, reduced procedure times (46±14 versus 38±13 minutes, =0.004), no further strokes and a low incidence of silent cerebral injury (10/53 patients; 19%) were noted. During short-term follow-up, 17/191 patients (9%) had a atrial tachyarrhythmia recurrence.

CONCLUSIONS

The pulsed field ablation device allows for simple and safe simple single shot pulmonary vein isolation using standard sedation protocols. Procedural speed and efficacy are remarkable and streamlining measures have added safety.

摘要

背景

脉冲场消融代表了一种针对心律失常(包括心房颤动)消融的特定能量源。本研究旨在描述一种新消融技术的采用和简化流程的过程。

方法

所有阵发性房颤患者(n=191;平均年龄 69±12 岁)均采用脉冲场消融消融设备进行导管消融,仅采用模拟镇静。在验证阶段(n=25),将设备电图质量与圆形标测导管进行比较,以评估肺静脉隔离,同时使用食管温度监测。在简化流程阶段(n=166),采用单导管方法。53 例患者行术后脑磁共振成像。52 例患者在术后第 1 天行食管内镜检查。采用 72 小时动态心电图进行随访。

结果

基于肺静脉,肺静脉隔离率为 100%,包括单次隔离率为 99.5%。脉冲场消融导管和圆形标测导管的电图信息 100%一致。未观察到食管温度升高或食管热损伤。发生了两例小卒中,可能是由于通过大口径鞘(13.8 F ID)更换导管时空气栓塞所致。在简化流程阶段,手术时间缩短(46±14 分钟比 38±13 分钟,=0.004),无进一步的中风,无症状性脑损伤发生率低(53 例患者中有 10 例;19%)。在短期随访中,191 例患者中有 17 例(9%)出现房性心动过速复发。

结论

脉冲场消融设备可使用标准镇静方案简单、安全地实现单次肺静脉隔离。手术速度和疗效显著,简化措施增加了安全性。