Russ W, Kling D, Sauerwein G, Hempelmann G
Acta Anaesthesiol Scand. 1987 Feb;31(2):111-6. doi: 10.1111/j.1399-6576.1987.tb02531.x.
In 39 patients undergoing aorto-coronary-bypass grafting, spectral analysis of the EEG (compressed spectral array: CSA) and calculation of spectral edge frequency (SEF) were performed. The effects of different temperatures and of perfusion pressure (PP) were analyzed. Predictable patterns were observed. During cooling on cardiopulmonary bypass (CPB), linear regression analysis revealed a close correlation between SEF and tympanic membrane (Tty) or nasopharyngeal temperature (Tnp). During rewarming, a nonlinear correlation between SEF and Tty or Tnp was found. Rectal temperature as well as blood temperature in the arterial or venous line of the oxygenator seemed to be less useful. The independence of SEF and PP was demonstrated during the whole procedure. At the onset of CPB, after correction of the aortic clamp for performance of the aortic anastomosis and after removal of the aortic clamp, bilateral EEG slowing of varying duration occurred in 20 patients. Comparison of mean SEF before and after CPB revealed a difference of about 5 Hz. In no patient were major neurological abnormalities observed postoperatively.
对39例行主动脉冠状动脉搭桥术的患者进行了脑电图频谱分析(压缩频谱阵列:CSA)并计算了频谱边缘频率(SEF)。分析了不同温度和灌注压(PP)的影响。观察到了可预测的模式。在体外循环(CPB)降温期间,线性回归分析显示SEF与鼓膜温度(Tty)或鼻咽温度(Tnp)之间存在密切相关性。在复温期间,发现SEF与Tty或Tnp之间存在非线性相关性。直肠温度以及氧合器动脉或静脉管路中的血液温度似乎不太有用。在整个手术过程中,SEF和PP是相互独立的。在CPB开始时,在为进行主动脉吻合而校正主动脉夹之后以及在移除主动脉夹之后,20例患者出现了不同持续时间的双侧脑电图减慢。比较CPB前后的平均SEF发现差异约为5Hz。术后未观察到任何患者有严重的神经功能异常。