Oral and Maxillofacial Reconstruction and Regeneration Laboratory, Southwest Medical University, Luzhou, 646000, China.
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatology Hospital of Southwest Medical University, Luzhou, China.
BMC Oral Health. 2022 Jun 6;22(1):222. doi: 10.1186/s12903-022-02253-8.
The high-speed hand-piece bur is one of the methods to perform tooth sectioning during the minimally traumatic extraction of impacted mandibular third molars. During tooth sectioning, the breakage of the bur might take place when it is improperly used. Three cases of the breakage and displacement of a high-speed hand-piece bur during extraction are reported, aiming to remind dental surgeons of this complication.
The bur fragment in case 1 was embedded in the mandibular bone under the previously removed crown of tooth 48 and distal to tooth 47. The bur fragment in case 2 was embedded in the lingual edge of the socket and partly beneath the mucosa on the lingual side. The position of the bur fragment in case 3 was similar to that of case 1 but was completely embedded in the spongious bone. The three cases were performed by first-year residents, and all of the bur fragments were successfully removed by attending doctors after accurately locating them by radiological examination.
In order to avoid breakage of the high-speed hand-piece bur, the number of uses of the bur should be monitored and the integrity and state of the bur should be carefully checked. Moreover, light pressure with little lateral force should be used during tooth sectioning. If bur breakage and displacement occur, the retrieval protocol should be determined based on the imaging findings and conducted as soon as possible to avoid serious consequences.
高速手机车针是微创拔除下颌阻生第三磨牙时进行牙体分切的方法之一。在分切过程中,如果使用不当,车针可能会折断。本文报告了 3 例高速手机车针在拔除过程中折断和移位的病例,旨在提醒口腔外科医生注意这一并发症。
在病例 1 中,车针碎片嵌入了之前已去除 48 号牙牙冠的下颌骨内,位于 47 号牙的远中。病例 2 中,车针碎片嵌入了牙槽窝的舌侧边缘,部分位于舌侧黏膜下。病例 3 中车针碎片的位置与病例 1 相似,但完全嵌入了松质骨中。这 3 例均由住院医师完成,所有车针碎片均通过放射检查准确定位后,由主治医生成功取出。
为了避免高速手机车针折断,应监测车针的使用次数,并仔细检查车针的完整性和状态。此外,在分切牙体时应使用轻压力,避免侧向力过大。如果发生车针折断和移位,应根据影像学检查结果确定取出方案,并尽快进行,以避免严重后果。