Dental Section, Department of Surgery, The Aga Khan University, Karachi, Pakistan.
BMC Oral Health. 2024 May 21;24(1):585. doi: 10.1186/s12903-024-04349-9.
Periodontal instrument fractures are rare events in dentistry, with limited literature available on their occurrence and management. This case report highlights an incident involving the fracture of a periodontal sickle scaler blade during manual instrumentation for the removal of calculus. The fracture occurred during instrumentation on the mesial surface of the maxillary right second molar, and the separated blade was subsequently pushed into the sulcus. A radiographic assessment was performed to verify the precise location of the fractured segment. Following confirmation, the broken blade was subsequently retrieved using curved artery forceps. The case report highlights factors contributing to instrument fractures, emphasizing the importance of instrument maintenance, sterilization cycles, and operator technique. Ethical considerations regarding patient disclosure, informed consent, and instrument retrieval methods are well discussed. This case underscores the importance of truthful communication, the proper use of instruments, equipment maintenance in dentistry, and the significance of ongoing professional development to enhance treatment safety, proficiency, and ethical standards in dental care.
牙周器械折断在牙科中较为罕见,其发生和处理的相关文献有限。本病例报告重点介绍了在手动器械去除牙石过程中牙周镰形刮治器刀片折断的事件。折断发生在上颌右侧第二磨牙近中面的器械操作过程中,分离的刀片随后被推入牙周袋。进行放射评估以验证折断部位的准确位置。确认后,使用弯血管钳取出折断的刀片。病例报告强调了导致器械折断的因素,重点介绍了器械维护、消毒循环和操作人员技术的重要性。对患者披露、知情同意和器械取出方法的伦理考虑进行了充分讨论。本病例强调了真实沟通、正确使用器械、牙科设备维护以及持续专业发展的重要性,以提高治疗安全性、熟练程度和牙科护理的伦理标准。