Two-dimensional shear wave elastography (2D-SWE) is a non-invasive method to quantitatively evaluate the liver stiffness (LS), allowing the detection of hepatic pathological changes in both dogs and humans. In dogs, some factors such as patient movement and respiration can cause artefacts and potential errors of measurements. Therefore, anaesthesia has been suggested to reduce the effect of the movement on 2D-SWE in dogs. This study was performed to evaluate the influence of an anaesthetic protocol on 2D-SWE measurements for assessment of LS in healthy dogs. Forty-five dogs were included and subjected to anaesthesia: in 11 dogs, the 2D-SWE was performed both before and under anaesthesia, in 19 dogs, the 2D-SWE was performed only when they were awake and in 15 dogs, the examination was carried out only under anaesthesia. The anaesthetic protocol was composed of intramuscular injection of a combination of dexmedetomidine, methadone and ketamine and intravenous administration of propofol for induction and isoflurane for maintenance. The variability of 2D-SWE values according to anaesthesia was evaluated. Median 2D-SWE values were significantly higher in anesthetized dogs compared to awake dogs either by considering separately the dogs in which the examination was performed both awake and under anaesthesia and by considering all dogs included. According to our study, anaesthesia helped to avoid challenges related to patient movement and respiration; however, it was a source of variability on 2D-SWE values, and this factor should be considered before performing 2D-SWE under anaesthesia.

摘要

二维剪切波弹性成像(2D-SWE)是一种定量评估肝脏硬度(LS)的非侵入性方法,可用于检测犬类和人类的肝脏病理变化。在犬类中,患者移动和呼吸等一些因素会导致伪像和测量的潜在误差。因此,有人建议使用麻醉来减少移动对犬类2D-SWE的影响。本研究旨在评估麻醉方案对健康犬类评估LS的2D-SWE测量值的影响。纳入45只犬并进行麻醉:11只犬在麻醉前和麻醉下均进行了2D-SWE检查,19只犬仅在清醒时进行了2D-SWE检查,15只犬仅在麻醉下进行了检查。麻醉方案包括肌肉注射右美托咪定、美沙酮和氯胺酮的组合,静脉注射丙泊酚诱导麻醉,异氟烷维持麻醉。评估了根据麻醉情况2D-SWE值的变异性。无论是分别考虑清醒和麻醉下均进行检查的犬只,还是考虑所有纳入的犬只,麻醉犬的2D-SWE值中位数均显著高于清醒犬。根据我们的研究,麻醉有助于避免与患者移动和呼吸相关的挑战;然而,它是2D-SWE值变异性的一个来源,在麻醉下进行2D-SWE检查之前应考虑这一因素。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/174f/9132446/9d9e5bf105ed/TVSM_A_2073138_F0001_OC.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验