Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.
CeramTec GmbH, Plochingen, Germany.
Clin Orthop Surg. 2022 Jun;14(2):191-195. doi: 10.4055/cios21102. Epub 2022 May 13.
In ceramic-on-ceramic total hip arthroplasty, firm locking is necessary between a ceramic liner and an acetabular metal shell to prevent dissociation of the liner from the metal shell. We evaluated surgeons' awareness of the technique for inserting the ceramic liner and measured the impaction force applied by surgeons during the insertion of the ceramic liner.
To evaluate the awareness, we conducted a survey using a questionnaire including techniques for ceramic liner insertion. The impaction force was measured using an impaction simulator in 224 surgeons.
Most surgeons answered that they cleaned and dried up the inner surface of the metal shell before inserting a ceramic liner (96.4% and 86.2%, respectively), and 74.6% checked the correct seating of the ceramic liner. However, only 23.2% correctly answered that a minimum of 2kN (a light strike) was necessary to obtain a sufficient fit between the metal shell and the ceramic liner. The impaction force was weaker than 2 kN in 9.4% of the surgeons.
Education about the adequate impaction force to obtain a firm fit of the ceramic liner is necessary for surgeons who perform total hip arthroplasty using ceramic-on-ceramic bearings.
在陶瓷对陶瓷全髋关节置换术中,需要确保陶瓷衬垫与髋臼金属外壳之间牢固锁定,以防止衬垫从金属外壳上分离。我们评估了外科医生对插入陶瓷衬垫技术的认识,并测量了外科医生在插入陶瓷衬垫过程中施加的撞击力。
为了评估意识,我们使用包括陶瓷衬垫插入技术在内的问卷调查进行了调查。使用撞击模拟器测量了 224 名外科医生的撞击力。
大多数外科医生回答说,他们在插入陶瓷衬垫之前会清洁并干燥金属壳的内表面(分别为 96.4%和 86.2%),并且 74.6%会检查陶瓷衬垫的正确位置。然而,只有 23.2%的人正确回答说,需要至少 2kN(轻击)的力才能使金属外壳和陶瓷衬垫之间获得足够的贴合。在 9.4%的外科医生中,撞击力小于 2kN。
对于使用陶瓷对陶瓷轴承进行全髋关节置换术的外科医生,需要进行关于获得陶瓷衬垫牢固贴合所需的适当撞击力的教育。